EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY 4.0

Diagnostic accuracy of using capnography in verification of nasogastric tube placement among adult patients in hospital settings: Protocol of a diagnostic study

Janita Pak Chun Chau iD, Danny Wah Kun Tong, Suzanne Hoi Shan Lo, Savina Yee Man Sze, Molly Lai Mei Kwok, Peter Chi Keung Lai, Harris Kai Cheong Lam, Josephine Yuen Man Chung, Xu Liu, Wai Tong Chien iD, Kai Chow Choi

PLOS ONE · 23.10.2023 · 18 (10) · e0292667

DOI: 10.1371/journal.pone.0292667 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift PLOS ONE, erschienen am 23.10.2023. Verfasst von Janita Pak Chun Chau und 10 weiteren Autor:innen. Beteiligte Einrichtung: Nethersole School of Nursing, The Chinese University of Hong Kong, Hong Kong, Hong Kong. Hauptthemen laut MEDLINE: Capnography, Carbon Dioxide. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hospital Authority.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine the diagnostic accuracy of end-tidal carbon dioxide (ETCO 2 ) detection using capnography for verifying the correct placement of nasogastric tubes (NGTs) among adult patients in hospital settings. Materials and methods A prospective observational diagnostic study will be conducted. Patients ≥ 18-year-old and requiring the insertion of an NGT will be recruited using a convenience sampling method from 39 general medical and geriatric wards, intensive care units, accident and emergency departments, and subacute/rehabilitation/infirmary wards in 21 acute or subacute/convalescent/extended care hospitals. ETCO 2 detection by sidestream capnography, which indicates an airway intubation of an NGT when a capnogram waveform or an ETCO 2 level > 10mmHg (1.33 kPa) occurs, will serve as the index test. The reference standards will be the X-ray performed and pH value of gastric aspiration (pH ≤ 5.5) after the index test. Each participant will be included only once. Sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve of capnography will be calculated to assess the diagnostic performance of capnography. The variability in diagnostic accuracy in participants with different characteristics will be explored by using chi-squared or Fisher’s exact tests. The time spent and the cost of the tests will be compared using the paired t-test. All statistical tests will be two-sided with a level of significance set at 0.05.

Discussion

This study will provide evidence on the diagnostic accuracy of capnography in verifying NGT placement and its applicability to patients in hospitals settings, since this evidence is limited in the current literature. In addition, it will help identify the optimal combination of tests in verifying the correct placement of NGTs and inform the update of clinical practice guidelines and stakeholders’ decisions on the adoption of ETCO 2 detection as a routine method for verifying NGT placement.

Trial registration

ClinicalTrials.gov ID: NCT05817864 .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CapnographyCarbon DioxideHumansAdultAgedAdolescentIntubation, GastrointestinalHospitalsIntensive Care UnitsObservational Studies as Topic

Substanzen

Carbon Dioxide

Autor:innen und Institutionen

  • Nethersole School of Nursing, The Chinese University of Hong Kong, Hong Kong, Hong Kong.
  • Nursing Services Department, Hospital Authority Hong Kong, Hong Kong, Hong Kong.
  • Shatin Hospital, Hospital Authority Hong Kong, Hong Kong, Hong Kong.
  • Queen Mary Hospital, Hospital Authority Hong Kong, Hong Kong, Hong Kong.
  • Ruttonjee and Tang Shiu Kin Hospitals, Hospital Authority Hong Kong, Hong Kong, Hong Kong.
  • Prince of Wales Hospital, Hospital Authority Hong Kong, Hong Kong, Hong Kong.

ORCID-Profile: Janita Pak Chun Chau, Wai Tong Chien

Förderung

  • Hospital Authority

Zitieren

APA

Chau, J. P. C., Tong, D. W. K., Lo, S. H. S., Sze, S. Y. M., Kwok, M. L. M., Lai, P. C. K., Lam, H. K. C., Chung, J. Y. M., Liu, X., Chien, W. T., & Choi, K. C. (2023). Diagnostic accuracy of using capnography in verification of nasogastric tube placement among adult patients in hospital settings: Protocol of a diagnostic study. PLOS ONE. https://doi.org/10.1371/journal.pone.0292667

Vancouver

Chau JPC, Tong DWK, Lo SHS, Sze SYM, Kwok MLM, Lai PCK, et al. Diagnostic accuracy of using capnography in verification of nasogastric tube placement among adult patients in hospital settings: Protocol of a diagnostic study. PLOS ONE. 2023. doi:10.1371/journal.pone.0292667

BibTeX
@article{Chau2023,
  author = {Chau, Janita Pak Chun and Tong, Danny Wah Kun and Lo, Suzanne Hoi Shan and Sze, Savina Yee Man and Kwok, Molly Lai Mei and Lai, Peter Chi Keung and Lam, Harris Kai Cheong and Chung, Josephine Yuen Man and Liu, Xu and Chien, Wai Tong and Choi, Kai Chow},
  title = {Diagnostic accuracy of using capnography in verification of nasogastric tube placement among adult patients in hospital settings: Protocol of a diagnostic study},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0292667}
}
Kostenlos starten →