EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Mechanical bone strength decreases considerably after microwave ablation–Ex-vivo and in-vivo analysis in sheep long bones

Hendricus Nijland iD, Jinwen Zhu, Thomas C Kwee, Ding-Jun Hao, Paul C Jutte

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0292177 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Hendricus Nijland und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, University Medical Center Groningen, Groningen, The Netherlands. Hauptthemen laut MEDLINE: Radiofrequency Ablation, Ablation Techniques, Catheter Ablation, Neoplasms. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Bone metastases are on the rise due to longer survival of cancer patients. Local tumor control is required for pain relief. Microwave ablation (MWA) is a technique for minimally invasive local tumor treatment. Tumor tissue is destroyed by application of local hyperthermia to induce necrosis. Given the most common setting of palliative care, it is generally considered beneficial for patients to start mobilizing directly following treatment. No data on mechanical strength in long bones after MWA have been published so far. Materials and methods In- and ex-vivo experiments on sheep tibias were performed with MWA in various combinations of settings for time and power. During the in-vivo part sheep were sacrificed one or six weeks after ablation. Mechanical strength was examined with a three-point bending test for ablations in the diaphysis and with an indentation test for ablations in the metaphysis.

Results

MWA does not decrease mechanical strength in the diaphysis. In the metaphysis strength decreased up to 50% six weeks after ablation, which was not seen directly after ablation.

Conclusion

MWA appears to decrease mechanical strength in long bone metaphysis up to 50% after six weeks, however strength remains sufficient for direct mobilization. The time before normal strength is regained after the remodeling phase is not known.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiofrequency AblationAblation TechniquesCatheter AblationNeoplasmsHumansAnimalsSheepMicrowavesTreatment Outcome

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, University Medical Center Groningen, Groningen, The Netherlands.
  • Department of Orthopaedic Surgery, HongHui Medical Center Xi'an, Xi'an, China.
  • Department of Radiology, University Medical Center Groningen, Groningen, The Netherlands.

ORCID-Profile: Hendricus Nijland

Zitieren

APA

Nijland, H., Zhu, J., Kwee, T. C., Hao, D. J., & Jutte, P. C. (2023). Mechanical bone strength decreases considerably after microwave ablation–Ex-vivo and in-vivo analysis in sheep long bones. PLOS ONE. https://doi.org/10.1371/journal.pone.0292177

Vancouver

Nijland H, Zhu J, Kwee TC, Hao DJ, Jutte PC. Mechanical bone strength decreases considerably after microwave ablation–Ex-vivo and in-vivo analysis in sheep long bones. PLOS ONE. 2023. doi:10.1371/journal.pone.0292177

BibTeX
@article{Nijland2023,
  author = {Nijland, Hendricus and Zhu, Jinwen and Kwee, Thomas C and Hao, Ding-Jun and Jutte, Paul C},
  title = {Mechanical bone strength decreases considerably after microwave ablation–Ex-vivo and in-vivo analysis in sheep long bones},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0292177}
}
Kostenlos starten →