A comparison of three different microwave systems for laparoscopic liver tumor ablation
Journal of Surgical Oncology · 2024
DOI: 10.1002/jso.27621 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Surgical Oncology, 2024. Verfasst von Eren Berber und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endocrine Surgery, Cleveland Clinic, Cleveland, Ohio, USA. Hauptthemen laut MEDLINE: Microwaves, Liver Neoplasms, Laparoscopy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Our aim was to perform a comparison of three current microwave ablation (MWA) systems widely used for laparoscopic liver ablations in terms of ablation kinetics and geometry of ablation zones.
Methods
This was a retrospective, institutional review board‐approved study comparing Emprint, Emprint HP, and NeuWave systems for laparoscopic liver ablation. Analyses were performed via Mann−Whitney U and χ 2 tests. Continuous data are presented as median (interquartile range).
Results
For Emprint, Emprint HP, and NeuWave groups, tumor size was 1.16 (0.8), 1.21 (0.7), and 1.27 (0.9) cm ( p = 0.54). Ablation time per lesion was 7 (6), 4 (2.8), and 4 (3.3) min ( p < 0.0001), yielding similar ablation zone volumes and margins. The time to first ablation bubble was 1 (0.13), 1.5 (0.85), and 0.75 (0.5) min, and total ablation times were 7 (4.4), 4 (2), and 3.5 (2.8) min ( p < 0.0001). The roundness index A, B, and transverse were 0.94, 0.98, and 0.79; 0.95, 0.95, and 0.78; and 1.02, 0.95, and 0.96.
Conclusions
Although a saline‐cooling system with Emprint system allowed for larger diameter spherical ablation zones to be created, it led to decreased efficiency compared to the CO 2 ‐cooled NeuWave system, which exposes the active antenna directly to tissue. Increased power delivered by Emprint HP improved the efficiency of saline‐cooled design, as demonstrated by faster ablation times.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Endocrine Surgery, Cleveland Clinic, Cleveland, Ohio, USA.
- Department of General Surgery, Cleveland Clinic, Cleveland, Ohio, USA.
Zitieren
APA
Berber, E., Sarioglu, A. G., & Akgun, E. (2024). A comparison of three different microwave systems for laparoscopic liver tumor ablation. Journal of Surgical Oncology. https://doi.org/10.1002/jso.27621
Vancouver
Berber E, Sarioglu AG, Akgun E. A comparison of three different microwave systems for laparoscopic liver tumor ablation. Journal of Surgical Oncology. 2024. doi:10.1002/jso.27621
BibTeX
@article{Berber2024,
author = {Berber, Eren and Sarioglu, Ali Gunduz and Akgun, Ege},
title = {A comparison of three different microwave systems for laparoscopic liver tumor ablation},
journal = {Journal of Surgical Oncology},
year = {2024},
doi = {10.1002/jso.27621}
}
EUVIMED