Vergleichsstudie in der Zeitschrift Journal of Surgical Oncology, 2024. Verfasst von Eren Berber und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endocrine Surgery, Cleveland Clinic, Cleveland, Ohio, USA. Hauptthemen laut MEDLINE: Microwaves, Liver Neoplasms, Laparoscopy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Our aim was to perform a comparison of three current microwave ablation (MWA) systems widely used for laparoscopic liver ablations in terms of ablation kinetics and geometry of ablation zones.

Methods

This was a retrospective, institutional review board‐approved study comparing Emprint, Emprint HP, and NeuWave systems for laparoscopic liver ablation. Analyses were performed via Mann−Whitney U and χ 2 tests. Continuous data are presented as median (interquartile range).

Results

For Emprint, Emprint HP, and NeuWave groups, tumor size was 1.16 (0.8), 1.21 (0.7), and 1.27 (0.9) cm ( p = 0.54). Ablation time per lesion was 7 (6), 4 (2.8), and 4 (3.3) min ( p < 0.0001), yielding similar ablation zone volumes and margins. The time to first ablation bubble was 1 (0.13), 1.5 (0.85), and 0.75 (0.5) min, and total ablation times were 7 (4.4), 4 (2), and 3.5 (2.8) min ( p < 0.0001). The roundness index A, B, and transverse were 0.94, 0.98, and 0.79; 0.95, 0.95, and 0.78; and 1.02, 0.95, and 0.96.

Conclusions

Although a saline‐cooling system with Emprint system allowed for larger diameter spherical ablation zones to be created, it led to decreased efficiency compared to the CO 2 ‐cooled NeuWave system, which exposes the active antenna directly to tissue. Increased power delivered by Emprint HP improved the efficiency of saline‐cooled design, as demonstrated by faster ablation times.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrowavesLiver NeoplasmsLaparoscopyHumansRetrospective StudiesMaleFemaleMiddle AgedAgedAblation TechniquesCatheter AblationCarcinoma, HepatocellularRadiofrequency Ablation

Stichwörter der Autor:innen

EmprintNeuWaveablation systemsliver tumorsmicrowave ablation

Autor:innen und Institutionen

  • Department of Endocrine Surgery, Cleveland Clinic, Cleveland, Ohio, USA.
  • Department of General Surgery, Cleveland Clinic, Cleveland, Ohio, USA.

Zitieren

APA

Berber, E., Sarioglu, A. G., & Akgun, E. (2024). A comparison of three different microwave systems for laparoscopic liver tumor ablation. Journal of Surgical Oncology. https://doi.org/10.1002/jso.27621

Vancouver

Berber E, Sarioglu AG, Akgun E. A comparison of three different microwave systems for laparoscopic liver tumor ablation. Journal of Surgical Oncology. 2024. doi:10.1002/jso.27621

BibTeX
@article{Berber2024,
  author = {Berber, Eren and Sarioglu, Ali Gunduz and Akgun, Ege},
  title = {A comparison of three different microwave systems for laparoscopic liver tumor ablation},
  journal = {Journal of Surgical Oncology},
  year = {2024},
  doi = {10.1002/jso.27621}
}
Kostenlos starten →