The dimensions of preformed nickel-titanium archwires measured at the bracket positions corresponding to the central incisor, canine, and first molar
American Journal of Orthodontics and Dentofacial Orthopedics · 2024
DOI: 10.1016/j.ajodo.2024.05.010 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Orthodontics and Dentofacial Orthopedics, 2024. Verfasst von Yuya Sugiyama und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, The Nippon Dental University Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Nickel, Orthodontic Wires, Molar, Titanium. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Variation in the thickness of commercially available preformed rectangular archwires at the bracket positions has not been thoroughly studied. Therefore, this study measured the edgewise (height) and flatwise (width) dimensions of preformed rectangular nickel-titanium (NiTi) archwires at bracket positions corresponding to the central incisor, canine, and first molar and compared them among bracket positions. METHODS: Sixty types of preformed rectangular NiTi mandibular archwires indicated as 0.019 × 0.025-in were obtained from 14 manufacturers. The height and width dimensions of archwires were measured at 4 points (3 bracket positions corresponding to the central incisor, canine, and first molar, and 1 terminal end) of each side of each archwire using a micrometer and compared with the indicated dimensions using 1-sample t tests. Furthermore, the measured dimensions were compared among the 3 bracket positions using a 1-way analysis of variance and Bonferroni post-hoc test. RESULTS: The measured dimensions were significantly smaller than the indicated dimensions for all points except the central incisor point for height and significantly smaller than the indicated dimensions for all points for width. Comparisons among points showed that for height, the central incisor point was significantly larger than the first molar and terminal points. However, no significant differences were found for width at any point. CONCLUSIONS: The measured dimensions of preformed NiTi archwires at the bracket positions were generally smaller than the indicated dimensions, with variations observed not only among products but also among manufacturers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Orthodontics, The Nippon Dental University Hospital, Tokyo, Japan.
- Department of Orthodontics, School of Life Dentistry at Tokyo, The Nippon Dental University, Tokyo, Japan. Electronic address: tochigi@tky.ndu.ac.jp.
- Department of Orthodontics, School of Life Dentistry at Tokyo, The Nippon Dental University, Tokyo, Japan.
Zitieren
APA
Sugiyama, Y., Tochigi, K., Tachi, A., & Arai, K. (2024). The dimensions of preformed nickel-titanium archwires measured at the bracket positions corresponding to the central incisor, canine, and first molar. American Journal of Orthodontics and Dentofacial Orthopedics. https://doi.org/10.1016/j.ajodo.2024.05.010
Vancouver
Sugiyama Y, Tochigi K, Tachi A, Arai K. The dimensions of preformed nickel-titanium archwires measured at the bracket positions corresponding to the central incisor, canine, and first molar. American Journal of Orthodontics and Dentofacial Orthopedics. 2024. doi:10.1016/j.ajodo.2024.05.010
BibTeX
@article{Sugiyama2024,
author = {Sugiyama, Yuya and Tochigi, Keisuke and Tachi, Akihiko and Arai, Kazuhito},
title = {The dimensions of preformed nickel-titanium archwires measured at the bracket positions corresponding to the central incisor, canine, and first molar},
journal = {American Journal of Orthodontics and Dentofacial Orthopedics},
year = {2024},
doi = {10.1016/j.ajodo.2024.05.010}
}
EUVIMED