EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

In-vitro accuracy of casts for orthodontic purposes obtained by a conventional and by a printer workflow

Sven Reich, Hannah Herstell, Stefan Raith, Christina Kühne, Saskia Berndt iD

PLOS ONE · 2023

DOI: 10.1371/journal.pone.0282840 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Sven Reich und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics and Biomaterials, RWTH Aachen University Hospital, Aachen, Germany. Hauptthemen laut MEDLINE: Computer-Aided Design, Imaging, Three-Dimensional. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Dentsply Sirona.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This in-vitro study was designed to investigate whether conventionally produced casts and printed casts for orthodontic purposes show comparable full-arch accuracy. To produce casts, either a conventional impression or a digital data set is needed. A fully dentate all ceramic master cast was digitized with an industrial scanner to obtain a digital reference cast [REF]. Intraoral scans [IOS] and alginate impressions were taken from the master cast so that ten printed and ten gypsum casts were obtained. The printed casts [DLP] were digitized by an industrial scanner and as well as the gypsum casts [GYPSUM]. The following absolute mean trueness evaluations by superimposition were accomplished: [REF vs. GYPSUM]; [REF vs. DLP]; [REF vs. IOS]; [IOS vs. DLP]. For precision analysis the data sets of [GYPSUM], [IOS] and [DLP] were available. The absolute mean trueness values were 68 μm ± 15 μm for [REF vs. GYPSUM], 46 μm ± 4 μm for [REF vs. DLP], 20 μm ± 2 μm for [REF vs. IOS] and 41 μm ± 4 μm for [IOS vs. DLP]. [REF vs. GYPSUM] and [REF vs. DLP], [REF vs. IOS], [REF vs. DLP] and [IOS vs. DLP] showed statistically significant differences. The precision values were 56 μm ± 17 μm for [GYPSUM], 25 μm ± 9 μm for [DLP] and 12 μm ± 2 μm for [IOS] and differed significantly among each other. In the present study the print workflow revealed superior results in comparison to the conventional workflow. Due to contrary deviations in the [REF vs. IOS] and the [IOS vs. DLP] data sets the overall trueness deviations was enhanced.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer-Aided DesignImaging, Three-DimensionalWorkflowCalcium SulfateModels, DentalDental Impression Technique

Substanzen

Calcium Sulfate

Autor:innen und Institutionen

  • Department of Prosthodontics and Biomaterials, RWTH Aachen University Hospital, Aachen, Germany.
  • Department of Oral and Maxillofacial Surgery, RWTH Aachen University Hospital, Aachen, Germany.

ORCID-Profile: Saskia Berndt

Förderung

  • Dentsply Sirona

Zitieren

APA

Reich, S., Herstell, H., Raith, S., Kühne, C., & Berndt, S. (2023). In-vitro accuracy of casts for orthodontic purposes obtained by a conventional and by a printer workflow. PLOS ONE. https://doi.org/10.1371/journal.pone.0282840

Vancouver

Reich S, Herstell H, Raith S, Kühne C, Berndt S. In-vitro accuracy of casts for orthodontic purposes obtained by a conventional and by a printer workflow. PLOS ONE. 2023. doi:10.1371/journal.pone.0282840

BibTeX
@article{Reich2023,
  author = {Reich, Sven and Herstell, Hannah and Raith, Stefan and Kühne, Christina and Berndt, Saskia},
  title = {In-vitro accuracy of casts for orthodontic purposes obtained by a conventional and by a printer workflow},
  journal = {PLOS ONE},
  year = {2023},
  doi = {10.1371/journal.pone.0282840}
}
Kostenlos starten →