Study on mechanical properties of corroded concrete columns strengthened with SMA wires
PLOS ONE · 06.02.2023 · 18 (2) · e0276280
DOI: 10.1371/journal.pone.0276280 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 06.02.2023. Verfasst von Qiang Pei und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Architectural Engineering, Dalian University, Dalian, China. Hauptthemen laut MEDLINE: Electric Wiring, Records. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Department of Science & Technology Guidance Plan Foundation of Liaoning Province, Scientific Research Project of Liaoning Provincial Department of Education.
Abstract (Originalsprache)
Ocean crossing bridges suffer from seawater corrosion all year round and their mechanical properties will be substantially diminished. In order to enhance the mechanical properties of reinforced concrete columns corroded by seawater, SMA wire is used to restrain the reinforced concrete columns corroded by seawater to study their mechanical properties. 14 specimens were produced through the test, and the natural seawater corrosion was simulated by preparing a certain concentration of synthetic seawater. The mechanical properties of SMA strengthened specimens and unreinforced specimens are compared and analyzed, including failure mode, hysteresis curve, bearing capacity, ductility, stiffness and energy dissipation; the effects of different synthetic seawater corrosion concentrations on the mechanical properties of reinforced concrete columns are discussed. The results show that the bearing capacity and stiffness of reinforced concrete columns subjected to synthetic seawater corrosion are substantially diminished than those of uncorroded specimens, and the bearing capacity of specimens decreases more with the increase of synthetic seawater corrosion concentration; synthetic seawater corrosion has obscure effect on the ductility and energy dissipation performance of the specimens. The mechanical properties of the corroded specimens strengthened with SMA wire have been substantially enhanced, particularly the energy dissipation performance and bearing capacity have been notably enhanced, and the ductility and stiffness have also been somewhat enhanced. At the same time, based on the test, the finite element model is created according to the test specimen, while the accuracy of the model is verified, and the effects of the spacing and diameter of SMA wire, the strength of concrete and the thickness of protective layer on the mechanical properties of the specimen are analyzed.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- College of Architectural Engineering, Dalian University, Dalian, China.
- Architecture and Civil Engineering Institute, Guangdong University of Petrochemical Technology, Maoming, China.
- School of Civil Engineering, Dalian Jiaotong University, Dalian, China.
ORCID-Profile: Qiang Pei
Förderung
- National Natural Science Foundation of China
- Department of Science & Technology Guidance Plan Foundation of Liaoning Province
- Scientific Research Project of Liaoning Provincial Department of Education
Zitieren
APA
Pei, Q., Cai, B., Xue, Z., Ding, Y., Cui, D., & Guo, Y. (2023). Study on mechanical properties of corroded concrete columns strengthened with SMA wires. PLOS ONE, 18(2), e0276280. https://doi.org/10.1371/journal.pone.0276280
Vancouver
Pei Q, Cai B, Xue Z, Ding Y, Cui D, Guo Y. Study on mechanical properties of corroded concrete columns strengthened with SMA wires. PLOS ONE. 2023;18(2):e0276280. doi:10.1371/journal.pone.0276280
BibTeX
@article{Pei2023,
author = {Pei, Qiang and Cai, Bangwen and Xue, Zhicheng and Ding, Yu and Cui, Di and Guo, Yun},
title = {Study on mechanical properties of corroded concrete columns strengthened with SMA wires},
journal = {PLOS ONE},
year = {2023},
volume = {18},
number = {2},
pages = {e0276280},
doi = {10.1371/journal.pone.0276280}
}