Highly accurate image registration for 3D multiplexed cyclic imaging using dense labeling in expandable tissue gels
PLOS Biology · 2025
DOI: 10.1371/journal.pbio.3003240 ↗At a glance
Journal article in PLOS Biology, 2025. Written by Hyunwoo Kim and 11 co-authors. Institution: Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea. Major MEDLINE topics: Imaging, Three-Dimensional. Cited 4 times so far (Crossref); 37 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Research Foundation of Korea (NRF), Korean government (MSIT), Bio & Medical Technology Development Program of the NRF.
Abstract (original language)
Multiplexed cyclic imaging in expandable tissue gels has been extensively studied to visualize numerous biomolecules at a nanoscale resolution in situ. Previous studies have employed sparse labels, such as DAPI or lectin staining, as registration markers. However, these sparse labels do not adequately capture the full extent of deformation across the entire region of interest. To overcome this challenge, we propose the use of dense labels, specifically fluorophore N -hydroxysuccinimide (NHS)-ester staining, as registration markers to achieve highly accurate image registration. We first tested several NHS-functionalized fluorophores as fiducial markers and identified the proper candidates for three-dimensional (3D) multiplexed cyclic imaging. We analyzed the registration accuracy between DAPI and NHS-ester staining and illustrated that dense label-based registration provides a more accurate registration performance. In the multiplexed imaging of expanded specimens, we observed that repetitive expansion/shrinking processes and chemical treatments for signal elimination can induce 3D nonlinear distortion. This sample distortion can be mitigated by re-embedding the tissue gel or replacing the chemical de-staining process with photobleaching-based signal removal or computational signal unmixing. With such an optimized experimental setup, we demonstrated 3D multiplexed cyclic imaging with nanoscale precision image registration. Finally, we prove that dense biological structures, such as actin, can be used as registration markers to achieve high registration accuracy. We anticipate that the proposed dense labeling strategy will overcome the technical limitations of multiplexed cyclic imaging in expandable tissue gels, offering high-precision registration. We expect it to be widely adopted by the biological and medical communities.
Subjects
MeSH terms (MEDLINE)
Substances
Authors and institutions
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea.
- Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea.
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea.
- KAIST Institute for Health Science and Technology, Daejeon, 34141, Republic of Korea.
- Department of Biological Sciences, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea.
ORCID profiles: Jae-Byum Chang
Funding
- National Research Foundation of Korea (NRF)
- Korean government (MSIT)
- Bio & Medical Technology Development Program of the NRF
- Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI)
- Ministry of Health & Welfare, Republic of Korea
- Korean National Research Foundation
- Bio & Medical Technology Development Program of Korean National Research Foundation
- Korea Health Technology R&D Project by Ministry of Health & Welfare
Cite
APA
Kim, H., Kim, J. G., Sim, J., Nam, H., Cho, I., Shin, H., Kwon, J., Song, D. H., Bae, S., Yoon, Y. G., Ku, T., & Chang, J. B. (2025). Highly accurate image registration for 3D multiplexed cyclic imaging using dense labeling in expandable tissue gels. PLOS Biology. https://doi.org/10.1371/journal.pbio.3003240
Vancouver
Kim H, Kim JG, Sim J, Nam H, Cho I, Shin H, et al. Highly accurate image registration for 3D multiplexed cyclic imaging using dense labeling in expandable tissue gels. PLOS Biology. 2025. doi:10.1371/journal.pbio.3003240
BibTeX
@article{Kim2025,
author = {Kim, Hyunwoo and Kim, Joon-Goon and Sim, Jueun and Nam, Hoyeon and Cho, In and Shin, Hyejin and Kwon, Junyoung and Song, Dae-Hyeon and Bae, Seoungbin and Yoon, Young-Gyu and Ku, Taeyun and Chang, Jae-Byum},
title = {Highly accurate image registration for 3D multiplexed cyclic imaging using dense labeling in expandable tissue gels},
journal = {PLOS Biology},
year = {2025},
doi = {10.1371/journal.pbio.3003240}
}
EUVIMED