Optical coherence tomography-based design for a real-time motion corrected scanning microscope

Stephen S Tucker, John T Giblin, Kivilcim Kiliç, Anderson Chen, Jianbo Tang, David A Boas

Optics Letters · 2023

DOI: 10.1364/ol.490087 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Letters, 2023. Verfasst von Stephen S Tucker und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Artifacts. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Division of Biological Infrastructure.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

While two-photon fluorescence microscopy is a powerful platform for the study of functional dynamics in living cells and tissues, the bulk motion inherent to these applications causes distortions. We have designed a motion tracking module based on spectral domain optical coherence tomography which compliments a laser scanning two-photon microscope with real-time corrective feedback. The module can be added to fluorescent imaging microscopes using a single dichroic and without additional contrast agents. We demonstrate that the system can track lateral displacements as large as 10 μ m at 5 Hz with latency under 14 ms and propose a scheme to extend the system to 3D correction with the addition of a remote focusing module. We also propose several ways to improve the module’s performance by reducing the feedback latency. We anticipate that this design can be adapted to other imaging modalities, enabling the study of samples subject to motion artifacts at higher resolution.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceArtifactsMotionMicroscopy, ConfocalMicroscopy, Fluorescence

Förderung

  • Division of Biological Infrastructure

Zitieren

APA

Tucker, S. S., Giblin, J. T., Kiliç, K., Chen, A., Tang, J., & Boas, D. A. (2023). Optical coherence tomography-based design for a real-time motion corrected scanning microscope. Optics Letters. https://doi.org/10.1364/ol.490087

Vancouver

Tucker SS, Giblin JT, Kiliç K, Chen A, Tang J, Boas DA. Optical coherence tomography-based design for a real-time motion corrected scanning microscope. Optics Letters. 2023. doi:10.1364/ol.490087

BibTeX
@article{Tucker2023,
  author = {Tucker, Stephen S and Giblin, John T and Kiliç, Kivilcim and Chen, Anderson and Tang, Jianbo and Boas, David A},
  title = {Optical coherence tomography-based design for a real-time motion corrected scanning microscope},
  journal = {Optics Letters},
  year = {2023},
  doi = {10.1364/ol.490087}
}