EUVIMEDEUVIMED entdecken
Crossref

Motion Artifact Correction for OCT Microvascular Images Based on Image Feature Matching

Xudong Chen, Zongqing Ma, Chongyang Wang, Jiaqi Cui, Fan Fan iD, Xinxiao Gao, Jiang Zhu

Journal of Biophotonics · 2024

DOI: 10.1002/jbio.202400198 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biophotonics, 2024. Verfasst von Xudong Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology Univ…. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Artifacts, Image Processing, Computer-Assisted, Microvessels. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, R&D Program of Beijing Municipal Education Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical coherence tomography angiography (OCTA), a functional extension of optical coherence tomography (OCT), is widely employed for high‐resolution imaging of microvascular networks. However, due to the relatively low scan rate of OCT, the artifacts caused by the involuntary bulk motion of tissues severely impact the visualization of microvascular networks. This study proposes a fast motion correction method based on image feature matching for OCT microvascular images. First, the rigid motion‐related mismatch between B‐scans is compensated through the image feature matching based on the improved oriented FAST and rotated BRIEF algorithm. Then, the axial motion within A‐scan lines in each B‐scan image is corrected according to the displacement deviation between the detected boundaries achieved by the Scharr operator in a non‐rigid transformation manner. Finally, an optimized intensity‐based Doppler variance algorithm is developed to enhance the robustness of the OCTA imaging. The experimental results demonstrate the effectiveness of the method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceArtifactsImage Processing, Computer-AssistedMicrovesselsAlgorithmsMotionHumans

Stichwörter der Autor:innen

image feature matchingmicrovascular networkmotion correctionoptical coherence tomographyoptical coherence tomography angiography

Autor:innen und Institutionen

  • Key Laboratory of the Ministry of Education for Optoelectronic Measurement Technology and Instrument, Beijing Information Science and Technology University, Beijing, China.
  • Beijing Anzhen Hospital, Capital Medical University, Beijing, China.

ORCID-Profile: Fan Fan

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • R&D Program of Beijing Municipal Education Commission
  • Young Backbone Teacher Support Plan of Beijing Information Science & Technology University

Zitieren

APA

Chen, X., Ma, Z., Wang, C., Cui, J., Fan, F., Gao, X., & Zhu, J. (2024). Motion Artifact Correction for OCT Microvascular Images Based on Image Feature Matching. Journal of Biophotonics. https://doi.org/10.1002/jbio.202400198

Vancouver

Chen X, Ma Z, Wang C, Cui J, Fan F, Gao X, et al. Motion Artifact Correction for OCT Microvascular Images Based on Image Feature Matching. Journal of Biophotonics. 2024. doi:10.1002/jbio.202400198

BibTeX
@article{Chen2024,
  author = {Chen, Xudong and Ma, Zongqing and Wang, Chongyang and Cui, Jiaqi and Fan, Fan and Gao, Xinxiao and Zhu, Jiang},
  title = {Motion Artifact Correction for OCT Microvascular Images Based on Image Feature Matching},
  journal = {Journal of Biophotonics},
  year = {2024},
  doi = {10.1002/jbio.202400198}
}
Kostenlos starten →