EUVIMEDEUVIMED entdecken
Crossref

Geometric calibration of central omnidirectional cameras under the unit-viewing sphere model

Zhuo Qing-Feng iD, Zhao Yue iD, Li Chao-Qian, Jiang Nan

Optics Express · 16.11.2026 · 34 (23) · 43507

DOI: 10.1364/oe.613936 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 03.11.2026. Verfasst von Zhuo Qing-Feng und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Mathematics and Statistics, Yunnan University, Kunming 650091, China. Die Arbeit nennt 24 Literaturangaben. Gefördert von: National Natural Science Foundation of China, 18th Postgraduate Research and Innovation Project of Yunnan University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a full-parameter calibration algorithm for central omnidirectional cameras, including central catadioptric and central fisheye cameras, unified under the unit-viewing sphere model. Existing methods typically require multiple line or chessboard patterns and are sensitive to radial distortion and image noise. In contrast, the proposed algorithm selects line images and views to identify those that provide valid calibration information. Building on this analysis, it requires only a mirror contour and one valid line image from a single view to linearly recover all intrinsic and spherical projection parameters. When at least four planar-point correspondences (or six world-point correspondences) are available, the extrinsic parameters and distortion coefficients can also be estimated. Notably, the effect of radial distortion can be approximately compensated by estimation biases in the effective focal length and the spherical projection parameter. Experimental results demonstrate that the proposed algorithm achieves robustness and accuracy comparable to classical methods, while enabling the selection of geometrically valid constraints.

Autor:innen und Institutionen

  • School of Mathematics and Statistics, Yunnan University, Kunming 650091, China.
  • Yunnan Key Laboratory of Statistical Modeling and Data Analysis, Kunming 650091, China.
  • Kunming Shipborne Equipment Research and Test Center of CSSC, Kunming, China.

ORCID-Profile: Zhuo Qing-Feng, Zhao Yue

Förderung

  • National Natural Science Foundation of China
  • 18th Postgraduate Research and Innovation Project of Yunnan University

Zitieren

APA

Qing-Feng, Z., Yue, Z., Chao-Qian, L., & Nan, J. (2026). Geometric calibration of central omnidirectional cameras under the unit-viewing sphere model. Optics Express, 34(23), 43507. https://doi.org/10.1364/oe.613936

Vancouver

Qing-Feng Z, Yue Z, Chao-Qian L, Nan J. Geometric calibration of central omnidirectional cameras under the unit-viewing sphere model. Optics Express. 2026;34(23):43507. doi:10.1364/oe.613936

BibTeX
@article{QingFeng2026,
  author = {Qing-Feng, Zhuo and Yue, Zhao and Chao-Qian, Li and Nan, Jiang},
  title = {Geometric calibration of central omnidirectional cameras under the unit-viewing sphere model},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {23},
  pages = {43507},
  doi = {10.1364/oe.613936}
}
Kostenlos starten →