Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026-01. Verfasst von Morten Sielnik Andersen und 4 weiteren Autor:innen. Beteiligte Einrichtung: SDU NanoSYD, University of Southern Denmark, Campusvej 55, Odense M, 5250, Denmark. Electronic address: mora@mci.sdu.dk. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Innovationsfonden, Aarhus Universitet, Syddansk Universitet.
Abstract (Originalsprache)
This work presents an adaptable and fully automated approach for calibrating hyperspectral images (HSI) acquired using a pushbroom (line-scan) system. The proposed method enables simultaneous spectral, intensity, and spatial calibration while determining the spectral and spatial resolution of the system, all within a single scan. Calibration is performed using a flexible multi-purpose calibration board designed to provide necessary reference data. Spectral calibration is achieved using an array of LEDs spanning the spectral range from visible to shortwave infrared (Vis-SWIR), enabling precise wavelength registration. Additionally, a narrowband laser diode determines the system's spectral resolution at one wavelength. Intensity calibration corrects for illumination inhomogeneities and pixel sensitivity variations using a highly reflective Restan plate. Spatial calibration ensures an accurate aspect ratio using a checkerboard pattern, while modulation transfer functions (MTFs) derived from line grids and edge transitions quantify the spatial resolution. A grayscale calibration module evaluates sensor intensity linearity. The calibration process is fully automated through a Python-based software package, which utilizes an ANN-driven object detection model to accurately extract pixel coordinates of each module. This modular approach allows for precise calibration of line-scan systems and can be adapted to other systems, e.g., snapshot. The method is evaluated using Newtec Vis-SWIR Oculus hyperspectral line-scan cameras, demonstrating consistent and accurate calibration.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- SDU NanoSYD, University of Southern Denmark, Campusvej 55, Odense M, 5250, Denmark. Electronic address: mora@mci.sdu.dk.
- Newtec Engineering A/S, Staermosegaardsvej 18, Odense M, 5250, Denmark.
- Plastic and Polymer Engineering, Department of Biological and Chemical Engineering, Aarhus University, Aabogade 40, Aarhus N, 8200, Denmark.
- SDU NanoSYD, University of Southern Denmark, Campusvej 55, Odense M, 5250, Denmark.
Förderung
- Innovationsfonden
- Aarhus Universitet
- Syddansk Universitet
Zitieren
APA
Andersen, M. S., Pedersen, J. C., Jørgensen, B., Hinge, M., & Eriksen, R. L. (2026). Modular calibration board for automated calibration of hyperspectral cameras. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 344, 126608. https://doi.org/10.1016/j.saa.2025.126608
Vancouver
Andersen MS, Pedersen JC, Jørgensen B, Hinge M, Eriksen RL. Modular calibration board for automated calibration of hyperspectral cameras. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026;344:126608. doi:10.1016/j.saa.2025.126608
BibTeX
@article{Andersen2026,
author = {Andersen, Morten Sielnik and Pedersen, Jens-Christian and Jørgensen, Bjarke and Hinge, Mogens and Eriksen, René Lynge},
title = {Modular calibration board for automated calibration of hyperspectral cameras},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2026},
volume = {344},
pages = {126608},
doi = {10.1016/j.saa.2025.126608}
}
EUVIMED