EUVIMEDEUVIMED entdecken
Crossref

Characterization of source coherence requirements for laboratory x-ray diffraction imaging

Sunghoon Choi, Sora Park, Jun-Tae Kang, Jin-Woo Jeong

Optics Express · 06.04.2026 · 34 (7) · 11847

DOI: 10.1364/oe.586471 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 24.03.2026. Verfasst von Sunghoon Choi und 3 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Gefördert von: Electronics and Telecommunications Research Institute, National Research Foundation of Korea.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Young’s double-slit (YDS) fringe visibility provides a detector-accessible measure of spatial coherence, but implementing hard-X-ray YDS experiments with compact laboratory sources is fundamentally constrained by the coherence–flux trade-off imposed by spatial filtering. Here we present an end-to-end simulation framework that couples SHADOW3 ray statistics with WOFRY wave-optics propagation to evaluate detector-level interference patterns and feasibility metrics under partial coherence. Partial coherence is defined directly at the pinhole plane by discretizing the pinhole-filtered angular spectrum into a weighted angular-tilt ensemble, which is propagated through Fresnel (pinhole to slit) and Fraunhofer (slit to detector) operators with energy-conserving binning onto an oversampled detector grid. Across parameter sweeps of effective source size w (20–200 µm), source–pinhole distance S (3.0–4.7 m), pinhole diameter D (3–10 µm), pinhole–slit distance R (0.01–1.0 m), and Gaussian relative bandwidth σ BW (0.1–5%), we evaluate Michelson visibility V , detector-ROI photon counts N det , and a photon-statistics-aware figure of merit FOM = V 2 N det . To capture bandwidth-driven degradation not reflected by global visibility alone, we additionally introduce a longitudinal-coherence wash-out metric LC ratio . The resulting inverse-design maps reveal two distinct operating regimes. For larger sources ( w ∼200 µm), the feasible design space becomes visibility-limited, while smaller sources ( w ∼50 µm) operate primarily in a throughput-limited regime where performance improves monotonically with photon acceptance. Absolute photon statistics are anchored by calibrating the pinhole-transmitted flux to a published laboratory benchmark (≈5 × 10 3 ph/s through a 5 µm pinhole at 0.1% σ BW ), enabling exposure-time interpretation of the design maps in experimentally meaningful units. The framework therefore provides a quantitative guideline for selecting source filtering and propagation geometry in compact laboratory YDS measurements under realistic coherence and photon-statistics constraints.

Förderung

  • Electronics and Telecommunications Research Institute
  • National Research Foundation of Korea

Zitieren

APA

Choi, S., Park, S., Kang, J. T., & Jeong, J. W. (2026). Characterization of source coherence requirements for laboratory x-ray diffraction imaging. Optics Express, 34(7), 11847. https://doi.org/10.1364/oe.586471

Vancouver

Choi S, Park S, Kang JT, Jeong JW. Characterization of source coherence requirements for laboratory x-ray diffraction imaging. Optics Express. 2026;34(7):11847. doi:10.1364/oe.586471

BibTeX
@article{Choi2026,
  author = {Choi, Sunghoon and Park, Sora and Kang, Jun-Tae and Jeong, Jin-Woo},
  title = {Characterization of source coherence requirements for laboratory x-ray diffraction imaging},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {7},
  pages = {11847},
  doi = {10.1364/oe.586471}
}
Kostenlos starten →