Laboratory three-dimensional X-ray micro-beam Laue diffraction
Journal of Applied Crystallography · 01.10.2025 · 58 (5) · 1742-1752
DOI: 10.1107/s1600576725007587 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Crystallography, online erschienen am 24.09.2025. Verfasst von Yubin Zhang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil and Mechanical Engineering, Technical University of Denmark, 2800Kongens Lyngby, Denmark. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Villum Fonden.
Abstract (Originalsprache)
The development of 3D non-destructive X-ray characterization techniques in home laboratories is essential for enabling many more researchers to perform 3D characterization daily, overcoming the limitations imposed by competitive and scarce access to synchrotron facilities. Recent efforts have focused on techniques such as laboratory diffraction contrast tomography (LabDCT). LabDCT allows 3D characterization of recrystallized grains with sizes larger than 15–20 µm, offering a boundary resolution of approximately 5 µm using commercial X-ray computed tomography (CT) systems. To enhance the capabilities of laboratory instruments, we have developed a new laboratory-based 3D X-ray micro-beam diffraction (Lab-3DµXRD) technique. Lab-3DµXRD combines the use of a focused polychromatic beam with a scanning-tomographic data acquisition routine to enable depth-resolved crystallographic orientation characterization. This work presents the first realization of Lab-3DµXRD, including hardware development through the integration of a newly developed Pt-coated twin paraboloidal capillary X-ray focusing optics into a conventional X-ray micro-computed tomography (µCT) system, as well as the development of data acquisition and processing software. The results are validated through comparisons with LabDCT and synchrotron phase contrast tomography. The findings clearly demonstrate the feasibility of Lab-3DµXRD, particularly in detecting smaller grains and providing intragranular information. Finally, we discuss future directions for developing Lab-3DµXRD into a versatile tool for studying materials with smaller grain sizes and high defect densities, including the potential of combining it with LabDCT and µCT for multiscale and multimodal microstructural characterization.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Civil and Mechanical Engineering, Technical University of Denmark, 2800Kongens Lyngby, Denmark.
- Observatoire de la Côte d'Azur, CNRS, Laboratoire Lagrange, Université Côte d'Azur, CS 34229 - F06304 Nice Cedex 4, France.
- Xnovo Technology ApS, 4600Køge, Denmark.
- Department of Physics, Technical University of Denmark, 2800Kongens Lyngby, Denmark.
ORCID-Profile: Yubin Zhang, Jacob Bowen, Henning Friis Poulsen
Förderung
- Villum Fonden
Zitieren
APA
Zhang, Y., Seret, A., Oddershede, J., Slyamov, A., Kehres, J., Bachmann, F., Gundlach, C., Olsen, U. L., Bowen, J., Poulsen, H. F., Lauridsen, E., & Jensen, D. J. (2025). Laboratory three-dimensional X-ray micro-beam Laue diffraction. Journal of Applied Crystallography, 58(5), 1742-1752. https://doi.org/10.1107/s1600576725007587
Vancouver
Zhang Y, Seret A, Oddershede J, Slyamov A, Kehres J, Bachmann F, et al. Laboratory three-dimensional X-ray micro-beam Laue diffraction. Journal of Applied Crystallography. 2025;58(5):1742-1752. doi:10.1107/s1600576725007587
BibTeX
@article{Zhang2025,
author = {Zhang, Yubin and Seret, Anthony and Oddershede, Jette and Slyamov, Azat and Kehres, Jan and Bachmann, Florian and Gundlach, Carsten and Olsen, Ulrik Lund and Bowen, Jacob and Poulsen, Henning Friis and Lauridsen, Erik and Jensen, Dorte Juul},
title = {Laboratory three-dimensional X-ray micro-beam Laue diffraction},
journal = {Journal of Applied Crystallography},
year = {2025},
volume = {58},
number = {5},
pages = {1742--1752},
doi = {10.1107/s1600576725007587}
}
EUVIMED