Percentage of ring artifacts correction (PRAC): a quantitative specific evaluation metric for the effect of ring artifacts correction in X-ray CT images
Optics Express · 2025
DOI: 10.1364/oe.568874 ↗Kurz gefasst
Fachartikel in der Zeitschrift Optics Express, 2025. Verfasst von Yang Zou und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Artifacts, Tomography, X-Ray Computed, Image Processing, Computer-Assisted. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Major State Basic Research Development Program of China, National Natural Science Foundation of China, Young Talent of Lifting Engineering for Science and Technology in Shandong, China.
Abstract (Originalsprache)
X-ray computed tomography (CT) plays an essential role in medical diagnostics, image-guided radiotherapy, and industrial inspection by providing high-resolution cross-sectional images. However, CT image quality can be compromised by ring artifacts—concentric rings that impair image integrity and complicate accurate diagnosis or inspection. Historically, evaluating ring artifact removal has relied on qualitative visual assessments by experts, which, while effective for obvious artifacts, lack reproducibility when identifying subtle structures. Traditional image quality metrics are not designed to assessing ring artifact correction and typically require a reference image, which is often unavailable in practical applications. To address these challenges, this study introduces Percentage of Ring Artifact Correction (PRAC), a metric designed specifically to evaluate the effectiveness of ring artifact correction in X-ray CT images without needing a reference image. PRAC quantifies artifact reduction by measuring the percentage decrease in standard deviation along the radial direction within a polar coordinate system, thus providing an accurate measure of artifact correction. Validation against established metrics like Root Mean Square Error (RMSE), Signal-to-Noise Ratio (SNR), Structural Similarity Index (SSIM), and Contrast-to-Noise Ratio (CNR) demonstrates PRAC's stability under varying noise conditions, sensitivity to minor variations, and correlation with ring artifact intensity. Our findings confirm PRAC's efficacy as a specialized metric for assessing ring artifact correction in CT images, reliably distinguishing the impact of various artifact removal algorithms, thereby enhancing the accuracy and reliability of CT imaging through a robust evaluation framework.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- Major State Basic Research Development Program of China
- National Natural Science Foundation of China
- Young Talent of Lifting Engineering for Science and Technology in Shandong, China
- Natural Science Foundation of Shandong Province
Zitieren
APA
Zou, Y., Qi, M., Wang, S., Zhang, J., Jiang, H., & Yao, S. (2025). Percentage of ring artifacts correction (PRAC): a quantitative specific evaluation metric for the effect of ring artifacts correction in X-ray CT images. Optics Express. https://doi.org/10.1364/oe.568874
Vancouver
Zou Y, Qi M, Wang S, Zhang J, Jiang H, Yao S. Percentage of ring artifacts correction (PRAC): a quantitative specific evaluation metric for the effect of ring artifacts correction in X-ray CT images. Optics Express. 2025. doi:10.1364/oe.568874
BibTeX
@article{Zou2025,
author = {Zou, Yang and Qi, Meili and Wang, Shuwei and Zhang, Jiale and Jiang, Huaidong and Yao, Shengkun},
title = {Percentage of ring artifacts correction (PRAC): a quantitative specific evaluation metric for the effect of ring artifacts correction in X-ray CT images},
journal = {Optics Express},
year = {2025},
doi = {10.1364/oe.568874}
}
EUVIMED