Load capacitance matching for resonant frequency adjusting-based multi-quartz tuning fork-enhanced laser spectroscopic sensing
Optics Express · 10.03.2025 · 33 (5) · 9423
DOI: 10.1364/oe.554266 ↗Kurz gefasst
Fachartikel in der Zeitschrift Optics Express, online erschienen am 24.02.2025. Verfasst von Hanxu Ma und 4 weiteren Autor:innen. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Laboratory of Opto-Electronic Information Acquisition and Manipulation (Anhui University), Ministry of Education, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
What we believe to be a novel load capacitance matching method is proposed for adjusting the resonant frequency of a quartz tuning fork (QTF) in a multi-QTF-based laser spectroscopy gas sensor for the first time. A sensing system integrating quartz-enhanced photoacoustic spectroscopy (QEPAS) and light-induced thermoelastic spectroscopy (LITES) was constructed to validate the proposed method. In this system, the QEPAS module consists of QTF1, while the LITES module is based on QTF2. Methane was chosen as the target gas to evaluate both the reliability of the method and the sensor's performance. Without frequency matching, the difference in resonant frequencies between QTF1 and QTF2 was 6.67 Hz, resulting in a superposition efficiency of only 33.7% for the QEPAS-LITES sensor. When the load capacitance matching method was applied, the load capacitance of QTF2 was adjusted to bring its resonant frequency closer to that of QTF1. This successfully matched the resonant frequencies of both QTFs, improving the superposition efficiency to 98.7%. The QEPAS-LITES sensor utilizing the load capacitance matching method demonstrated a strong linear concentration response. Additionally, long-term stability was evaluated through Allan deviation analysis. With an average time of 100 s, the minimum detection limit of the QEPAS-LITES sensor system was improved to 5.91 ppm.
Förderung
- National Natural Science Foundation of China
- Key Laboratory of Opto-Electronic Information Acquisition and Manipulation (Anhui University), Ministry of Education
- Fundamental Research Funds for the Central Universities
- Heilongjiang Postdoctoral Fund
- Natural Science Foundation of Heilongjiang Province
- China Postdoctoral Science Foundation
Zitieren
APA
Ma, H., Qiao, S., He, Y., Zhang, C., & Ma, Y. (2025). Load capacitance matching for resonant frequency adjusting-based multi-quartz tuning fork-enhanced laser spectroscopic sensing. Optics Express, 33(5), 9423. https://doi.org/10.1364/oe.554266
Vancouver
Ma H, Qiao S, He Y, Zhang C, Ma Y. Load capacitance matching for resonant frequency adjusting-based multi-quartz tuning fork-enhanced laser spectroscopic sensing. Optics Express. 2025;33(5):9423. doi:10.1364/oe.554266
BibTeX
@article{Ma2025,
author = {Ma, Hanxu and Qiao, Shunda and He, Ying and Zhang, Chu and Ma, Yufei},
title = {Load capacitance matching for resonant frequency adjusting-based multi-quartz tuning fork-enhanced laser spectroscopic sensing},
journal = {Optics Express},
year = {2025},
volume = {33},
number = {5},
pages = {9423},
doi = {10.1364/oe.554266}
}
EUVIMED