EUVIMEDEUVIMED entdecken
Crossref

Asymmetric Tongs Induced Frequency Splitting Achieving Simultaneous Two-Component Gas Sensing with a Single Quartz Tuning Fork in Two Independent Resonant Modes

Shunda Qiao iD, Ziheng Lv, Bangyu Liu, Hanxu Ma iD, Ying He iD, Haiyue Sun, Yufei Ma iD

ACS Sensors · 28.08.2026 · 11 (8) · 7104-7114

DOI: 10.1021/acssensors.6c01364 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 22.07.2026. Verfasst von Shunda Qiao und 6 weiteren Autor:innen. Beteiligte Einrichtung: National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin150001, China. Hauptthemen laut MEDLINE: Quartz, Acetylene, Methane, Gases. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 63 Literaturangaben. Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation, Natural Science Foundation of Heilongjiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, a highly sensitive light-induced thermoelastic spectroscopy (LITES)-based dual-gas simultaneous sensor by utilizing an asymmetric quartz tuning fork (AQTF) was reported for the first time. Using a standard commercial QTF as the substrate, the AQTF was constructed through a mechanical assembly-based tuning method. The resonant frequency of the AQTF was theoretically derived, and its resonance characteristics and modal behavior were investigated via finite-element analysis. The results indicate that by introducing an asymmetric configuration, the standard commercial QTF achieves clear resonance frequency splitting into two separate peaks. The corresponding vibration modes are both of the in-plane symmetric type, while the two are mutually independent and exert no interference on each other. This therefore lays a foundation for achieving simultaneous dual-gas sensing with a single QTF. Methane (CH4) and acetylene (C2H2) were chosen as the target to investigate the sensor performance. To enhance the detection sensitivity, a multipass cell with an absorption path length of 40 m was employed, and a transimpedance amplifier was used to amplify the electrical signal generated by the AQTF. When the integration time of the LITES system was increased to 200 s, the minimum detection limits for simultaneous CH4 and C2H2 detection were obtained to be 65.72 and 19.85 ppb, respectively.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

QuartzAcetyleneMethaneGasesSpectrum AnalysisVibration

Stichwörter der Autor:innen

LITESasymmetric tongsdual-gas simultaneous sensingfrequency splittingquartz tuning fork

Substanzen

QuartzAcetyleneMethaneGases

Autor:innen und Institutionen

  • National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin150001, China.
  • Zhengzhou Research Institute, Harbin Institute of Technology , Zhengzhou450008, China.

ORCID-Profile: Shunda Qiao, Hanxu Ma, Ying He, Yufei Ma

Förderung

  • National Natural Science Foundation of China
  • China Postdoctoral Science Foundation
  • Natural Science Foundation of Heilongjiang Province
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Qiao, S., Lv, Z., Liu, B., Ma, H., He, Y., Sun, H., & Ma, Y. (2026). Asymmetric Tongs Induced Frequency Splitting Achieving Simultaneous Two-Component Gas Sensing with a Single Quartz Tuning Fork in Two Independent Resonant Modes. ACS Sensors, 11(8), 7104-7114. https://doi.org/10.1021/acssensors.6c01364

Vancouver

Qiao S, Lv Z, Liu B, Ma H, He Y, Sun H, et al. Asymmetric Tongs Induced Frequency Splitting Achieving Simultaneous Two-Component Gas Sensing with a Single Quartz Tuning Fork in Two Independent Resonant Modes. ACS Sensors. 2026;11(8):7104-7114. doi:10.1021/acssensors.6c01364

BibTeX
@article{Qiao2026,
  author = {Qiao, Shunda and Lv, Ziheng and Liu, Bangyu and Ma, Hanxu and He, Ying and Sun, Haiyue and Ma, Yufei},
  title = {Asymmetric Tongs Induced Frequency Splitting Achieving Simultaneous Two-Component Gas Sensing with a Single Quartz Tuning Fork in Two Independent Resonant Modes},
  journal = {ACS Sensors},
  year = {2026},
  volume = {11},
  number = {8},
  pages = {7104--7114},
  doi = {10.1021/acssensors.6c01364}
}
Kostenlos starten →