EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pixelwise immersion factor calibration for underwater hyperspectral imaging instruments

Hongbo Liu, Natalie Summers, Yi-Chun Chen, Håvard Snefjellå Løvås, Geir Johnsen, Daniel Koestner, Camilla Sætre, Børge Hamre

Optics Express · 20.05.2024 · 32 (11) · 19854

DOI: 10.1364/oe.523641 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 14.05.2024. Verfasst von Hongbo Liu und 7 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitetet i Bergen, Norges Forskningsråd.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In situ spectral reflectance initially captured at high spatial resolution with underwater hyperspectral imaging (UHI) is effective for classification and quantification in oceanic biogeochemical studies; however, the measured spectral radiance is rarely used as an absolute quantity due to challenges in calibration of UHI instruments. In this paper, a commercial UHI instrument was calibrated for radiometric flat field response and pixelwise immersion effect to support in situ measurement of absolute spectral radiance. The radiometric and immersion factor calibrations of the UHI instrument were evaluated quantitatively through comparative experiments with a spectroradiometer and a spectrometer. Results show that the immersion factor of the center pixel of the tested UHI instrument was 1.763 in pure water at 600 nm, and the averaged difference in immersion factor between the center and edge pixel of the UHI instrument in the visible light band was only 1∼3% across its half angle field of view of 35° in air. The new calibration coefficients were further used to calculate the spectral radiance of transmitted sunlight through ice algae clusters in sea ice measured by the UHI instrument during an Arctic under-ice bio-optical survey.

Förderung

  • Universitetet i Bergen
  • Norges Forskningsråd

Zitieren

APA

Liu, H., Summers, N., Chen, Y. C., Løvås, H. S., Johnsen, G., Koestner, D., Sætre, C., & Hamre, B. (2024). Pixelwise immersion factor calibration for underwater hyperspectral imaging instruments. Optics Express, 32(11), 19854. https://doi.org/10.1364/oe.523641

Vancouver

Liu H, Summers N, Chen YC, Løvås HS, Johnsen G, Koestner D, et al. Pixelwise immersion factor calibration for underwater hyperspectral imaging instruments. Optics Express. 2024;32(11):19854. doi:10.1364/oe.523641

BibTeX
@article{Liu2024,
  author = {Liu, Hongbo and Summers, Natalie and Chen, Yi-Chun and Løvås, Håvard Snefjellå and Johnsen, Geir and Koestner, Daniel and Sætre, Camilla and Hamre, Børge},
  title = {Pixelwise immersion factor calibration for underwater hyperspectral imaging instruments},
  journal = {Optics Express},
  year = {2024},
  volume = {32},
  number = {11},
  pages = {19854},
  doi = {10.1364/oe.523641}
}