Incoherent partial superposition modeling for single-shot angle-resolved ellipsometry measurement of thin films on transparent substrates

Lihua Peng, Jian Wang, Feng Gao, Jun Zhang, Wenzheng Zhai, Liping Zhou, Xiangqian Jiang

Optics Express · 22.04.2024 · 32 (9) · 15774

DOI: 10.1364/oe.517216 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 15.04.2024. Verfasst von Lihua Peng und 6 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Knowledge Innovation Program of Wuhan-Basic Research.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ellipsometric measurement of transparent samples suffers from substrate backside reflection challenges, including incoherent and partial superposition issues. The recently developed angle-resolved ellipsometry (ARE) can naturally eliminate the backside reflections of substrates with a micro-spot equivalent thickness or thicker; however, for thinner substrates, ARE working with general incoherent backside reflection models shows significant inaccuracy or measurement failure. In this paper, an incoherent partial superposition (IPS) model is proposed to characterize the optical superposition effect between the frontside and uncertain backside reflections from an unknown substrate. IPS introduces a cosine-like correction of the backside reflection, corresponding to the overlapping-area change of backside and frontside reflections along with incident angles. Benefiting from ARE’s wide-angle spectral imaging capability, IPS achieves single-shot measurement of thin film thicknesses on transparent substrates of unknown thickness. An ARE system was built and calibrated regarding the linear relationship between the cosine-corrected angular frequencies and substrate thicknesses. Then, commercial ITO films on glasses of different thicknesses ranging from 200 to 1000 µm were measured. Experimental results show that IPS-ARE results in a root-mean-square accuracy error of ∼1 nm in film thickness measurement and provides a ∼77% error reduction from general incoherent backside reflection models.

Förderung

  • National Natural Science Foundation of China
  • National Key Research and Development Program of China
  • Knowledge Innovation Program of Wuhan-Basic Research

Zitieren

APA

Peng, L., Wang, J., Gao, F., Zhang, J., Zhai, W., Zhou, L., & Jiang, X. (2024). Incoherent partial superposition modeling for single-shot angle-resolved ellipsometry measurement of thin films on transparent substrates. Optics Express, 32(9), 15774. https://doi.org/10.1364/oe.517216

Vancouver

Peng L, Wang J, Gao F, Zhang J, Zhai W, Zhou L, et al. Incoherent partial superposition modeling for single-shot angle-resolved ellipsometry measurement of thin films on transparent substrates. Optics Express. 2024;32(9):15774. doi:10.1364/oe.517216

BibTeX
@article{Peng2024,
  author = {Peng, Lihua and Wang, Jian and Gao, Feng and Zhang, Jun and Zhai, Wenzheng and Zhou, Liping and Jiang, Xiangqian},
  title = {Incoherent partial superposition modeling for single-shot angle-resolved ellipsometry measurement of thin films on transparent substrates},
  journal = {Optics Express},
  year = {2024},
  volume = {32},
  number = {9},
  pages = {15774},
  doi = {10.1364/oe.517216}
}
Kostenlos starten →