EUVIMEDEUVIMED entdecken
Crossref

High accuracy calibration method for multi-line structured light three-dimensional scanning measurement system based on grating diffraction

Yao Wang, Peng Zhou, Chuanwei Yao, Hengyu Wang, Bin Lin

Optics Express · 01.01.2024 · 32 (1) · 691

DOI: 10.1364/oe.496579 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 21.12.2023. Verfasst von Yao Wang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 19 Literaturangaben. Gefördert von: National Key Research and Development Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multi-line structured light three-dimensional (3D) scanning measurement system enables to obtain the richer 3D profile data of the object simultaneously during one frame, ensuring high accuracy while structured light is deformed for the modulation by the object. Nevertheless, current calibration methods cannot fully take advantage of its high precision. In this paper, a fast and high-accuracy 3D measurement system based on multi-line lasers with a spatially precise structure via integrating a diffraction grating was proposed. This helps achieve precise calibration results of the light planes by introducing spatial constraint relations of the diffractive light, thus improving measurement accuracy. The operating principle and the workflow of the proposed system were described in detail. The measurement accuracy of the developed prototype was verified through contrastive experiments. At a working distance of 400 mm, the results show that the root mean square error (RMSE) of the proposed system is 0.083 mm, which is improved by 37.6% compared to the traditional calibration method of light planes for the ranging system. The system utilizing a grating that facilitates the integration of the device has great application value.

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Wang, Y., Zhou, P., Yao, C., Wang, H., & Lin, B. (2024). High accuracy calibration method for multi-line structured light three-dimensional scanning measurement system based on grating diffraction. Optics Express, 32(1), 691. https://doi.org/10.1364/oe.496579

Vancouver

Wang Y, Zhou P, Yao C, Wang H, Lin B. High accuracy calibration method for multi-line structured light three-dimensional scanning measurement system based on grating diffraction. Optics Express. 2024;32(1):691. doi:10.1364/oe.496579

BibTeX
@article{Wang2024,
  author = {Wang, Yao and Zhou, Peng and Yao, Chuanwei and Wang, Hengyu and Lin, Bin},
  title = {High accuracy calibration method for multi-line structured light three-dimensional scanning measurement system based on grating diffraction},
  journal = {Optics Express},
  year = {2024},
  volume = {32},
  number = {1},
  pages = {691},
  doi = {10.1364/oe.496579}
}