EUVIMEDEUVIMED entdecken
Crossref

Contactless speckle plethysmography from the face: approach and opportunities

Ilde Lorato, Jorge Herranz, Lena Schnitzler, Maartje Hoogeveen, Marc Verhoeven, Jesse Kling, Evelien Hermeling

Biomedical Optics Express · 01.12.2026 · 17 (12) · 6072

DOI: 10.1364/boe.608370 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 03.11.2026. Verfasst von Ilde Lorato und 6 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Measurement of vital signs like heart rate (HR) often requires direct contact between patient and device, which is not always possible or desirable. Alternative contactless solutions struggle to provide sufficient accuracy. This work introduces a contactless method for monitoring vital signs from the face, speckle plethysmography (SPG). SPG utilizes laser-generated speckle patterns to detect physiological changes. An algorithm called speckle density is proposed to enhance robustness against light fluctuations, outperforming the traditional speckle contrast method. Eleven healthy volunteers participated in controlled experiments comparing SPG-derived HR and respiratory rate (RR) to reference devices. The speckle density method achieved significantly lower mean absolute error in HR estimation under dynamic lighting, 1 beat per minute (bpm) vs. 16 bpm of speckle contrast and maintained comparable accuracy in stable conditions. RR estimation also showed strong agreement with reference data. This is the first work proving SPG signal extraction from facial videos at a 60 cm distance, validating its potential for contactless vital signs monitoring.

Zitieren

APA

Lorato, I., Herranz, J., Schnitzler, L., Hoogeveen, M., Verhoeven, M., Kling, J., & Hermeling, E. (2026). Contactless speckle plethysmography from the face: approach and opportunities. Biomedical Optics Express, 17(12), 6072. https://doi.org/10.1364/boe.608370

Vancouver

Lorato I, Herranz J, Schnitzler L, Hoogeveen M, Verhoeven M, Kling J, et al. Contactless speckle plethysmography from the face: approach and opportunities. Biomedical Optics Express. 2026;17(12):6072. doi:10.1364/boe.608370

BibTeX
@article{Lorato2026,
  author = {Lorato, Ilde and Herranz, Jorge and Schnitzler, Lena and Hoogeveen, Maartje and Verhoeven, Marc and Kling, Jesse and Hermeling, Evelien},
  title = {Contactless speckle plethysmography from the face: approach and opportunities},
  journal = {Biomedical Optics Express},
  year = {2026},
  volume = {17},
  number = {12},
  pages = {6072},
  doi = {10.1364/boe.608370}
}