Rolling shutter speckle plethysmography for quantitative cardiovascular monitoring
Biomedical Optics Express · 01.03.2024 · 15 (3) · 1540
DOI: 10.1364/boe.511755 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 09.02.2024. Verfasst von Yujin Lee und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
We propose a new speckle-based plethysmography technique, termed rolling shutter speckle plethysmography (RSSPG), which can quantitatively measure the velocity and volume fluctuations of blood flow during the cardiac cycle. Our technique is based on the rolling shutter speckle imaging, where the short row-by-row time differences in the rolling shutter image sensors are used to measure the temporal decorrelation behavior of vertically elongated speckles from a single image capture. Temporal analysis of the speckle field provides rich information regarding the dynamics of the scattering media, such as both the dynamic scattering fraction and the speckle decorrelation time. Using a sequence of images, RSSPG can monitor fluctuations in the blood flow dynamics while separating velocity and volume changes in blood vessels and obtaining high-quality plethysmography waveforms compared to regular photoplethysmography. We demonstrate the quantitative RSSPG based on accurate fitting of the speckle dynamics model, as well as the qualitative RSSPG based on simple row-by-row correlation (RIC) calculation for fast and robust analysis. Based on exploratory in vivo experiment, we show that RSSPG can reliably measure pulsatile waveforms and heart rate variations in various conditions, potentially providing physiologically relevant information for cardiovascular monitoring.
Autor:innen und Institutionen
- School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea.
ORCID-Profile: Yujin Lee, Sangjun Byun, Changyoon Yi, Jaewoo Jung, Seung Ah Lee
Förderung
- National Research Foundation of Korea
Zitieren
APA
Lee, Y., Byun, S., Yi, C., Jung, J., & Lee, S. A. (2024). Rolling shutter speckle plethysmography for quantitative cardiovascular monitoring. Biomedical Optics Express, 15(3), 1540. https://doi.org/10.1364/boe.511755
Vancouver
Lee Y, Byun S, Yi C, Jung J, Lee SA. Rolling shutter speckle plethysmography for quantitative cardiovascular monitoring. Biomedical Optics Express. 2024;15(3):1540. doi:10.1364/boe.511755
BibTeX
@article{Lee2024,
author = {Lee, Yujin and Byun, Sangjun and Yi, Changyoon and Jung, Jaewoo and Lee, Seung Ah},
title = {Rolling shutter speckle plethysmography for quantitative cardiovascular monitoring},
journal = {Biomedical Optics Express},
year = {2024},
volume = {15},
number = {3},
pages = {1540},
doi = {10.1364/boe.511755}
}
EUVIMED