Characterization of a fiber-coupled SPAD camera system for deep-tissue blood-flow measurement using diffuse correlation spectroscopy
Biomedical Optics Express · 01.04.2026 · 17 (4) · 2081
DOI: 10.1364/boe.588814 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 27.03.2026. Verfasst von Christopher H Moore und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA. Die Arbeit nennt 57 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
Diffuse correlation spectroscopy (DCS) is a promising technique for noninvasive measurement of blood flow, especially cerebral blood flow, where other noninvasive techniques have shortcomings. Conventional DCS often requires multiple simultaneous measurements to enhance the signal-to-noise ratio (SNR) when probing deep into the brain with large source-detector separations, where photons are scarce. However, this limits scalability when using discrete optical detectors. This study demonstrates the application of the 250 × 500 single-photon avalanche diode (SPAD) array, SwissSPAD3, coupled with a custom field-programmable gate array (FPGA) design, which enables significant increases in SNR compared to conventional DCS systems. We validate a fiber-coupled SPAD camera system against a lab-standard CW-DCS system in two-layer liquid phantoms and in human measurements, and demonstrate robust blood-flow tracking at source-detector separations up to 3.25 cm. These results support SPAD-based parallel detection as a scalable route to improved deep-tissue DCS performance in humans.
Autor:innen und Institutionen
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA.
- Advanced Quantum Architecture Laboratory, École polytechnique fédérale de Lausanne, Rue de la Maladière 71B, Neuchâtel, NE 2000, Switzerland.
- Department of Electrical and Computer Engineering, Stony Brook University, Stony Brook, NY, USA.
ORCID-Profile: Christopher H Moore, Michael A Wayne, Claudio Bruschini, Edoardo Charbon, Ulas Sunar
Förderung
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Moore, C. H., Wayne, M. A., Ulku, A. C., Mos, P., Bruschini, C., Charbon, E., & Sunar, U. (2026). Characterization of a fiber-coupled SPAD camera system for deep-tissue blood-flow measurement using diffuse correlation spectroscopy. Biomedical Optics Express, 17(4), 2081. https://doi.org/10.1364/boe.588814
Vancouver
Moore CH, Wayne MA, Ulku AC, Mos P, Bruschini C, Charbon E, et al. Characterization of a fiber-coupled SPAD camera system for deep-tissue blood-flow measurement using diffuse correlation spectroscopy. Biomedical Optics Express. 2026;17(4):2081. doi:10.1364/boe.588814
BibTeX
@article{Moore2026,
author = {Moore, Christopher H and Wayne, Michael A and Ulku, Arin C and Mos, Paul and Bruschini, Claudio and Charbon, Edoardo and Sunar, Ulas},
title = {Characterization of a fiber-coupled SPAD camera system for deep-tissue blood-flow measurement using diffuse correlation spectroscopy},
journal = {Biomedical Optics Express},
year = {2026},
volume = {17},
number = {4},
pages = {2081},
doi = {10.1364/boe.588814}
}
EUVIMED