Time-domain diffuse correlation spectroscopy at large source detector separation for cerebral blood flow recovery

Neda Mogharari, Stanisław Wojtkiewicz iD, Dawid Borycki iD, Adam Liebert iD, Michał Kacprzak

Biomedical Optics Express · 01.07.2024 · 15 (7) · 4330

DOI: 10.1364/boe.523514 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 26.06.2024. Verfasst von Neda Mogharari und 4 weiteren Autor:innen. Beteiligte Einrichtung: Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Poland. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Narodowe Centrum Nauki.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Time-domain diffuse correlation spectroscopy (td-DCS) enables the depth discrimination in tissue’s blood flow recovery, considering the fraction of photons detected with higher time of flight (TOF) and longer pathlength through the tissue. However, the recovery result depends on factors such as the instrument response function (IRF), analyzed TOF gate start time, gate width and the source-detector separation (SDS). In this research we evaluate the performance of the td-DCS technique at three SDSs of 1.5, 2 and 2.5 cm to recover cerebral blood flow (CBF). To do that we presented comprehensive characterization of the td-DCS system through a series of phantom experiments. First by quality metrices such as coefficient of variation and contrast-to-noise ratios, we identified optimal time gate(s) of the TOF to extract dynamics of particles. Then using sensitivity metrices, each SDS ability to detect dynamics of particles in superficial and deeper layer was evaluated. Finally, td-DCS at each SDS was tested on healthy volunteers during cuff occlusion test and breathing tasks. According to phantom measurements, the sensitivity to estimate perfusion within the deep layer located at depth of 1.5 cm from the surface can be increased more than two times when the SDS increases from 1.5 cm to 2.5 cm.

Autor:innen und Institutionen

  • Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Poland.
  • Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, Poland.

ORCID-Profile: Stanisław Wojtkiewicz, Dawid Borycki, Adam Liebert

Förderung

  • Narodowe Centrum Nauki

Zitieren

APA

Mogharari, N., Wojtkiewicz, S., Borycki, D., Liebert, A., & Kacprzak, M. (2024). Time-domain diffuse correlation spectroscopy at large source detector separation for cerebral blood flow recovery. Biomedical Optics Express, 15(7), 4330. https://doi.org/10.1364/boe.523514

Vancouver

Mogharari N, Wojtkiewicz S, Borycki D, Liebert A, Kacprzak M. Time-domain diffuse correlation spectroscopy at large source detector separation for cerebral blood flow recovery. Biomedical Optics Express. 2024;15(7):4330. doi:10.1364/boe.523514

BibTeX
@article{Mogharari2024,
  author = {Mogharari, Neda and Wojtkiewicz, Stanisław and Borycki, Dawid and Liebert, Adam and Kacprzak, Michał},
  title = {Time-domain diffuse correlation spectroscopy at large source detector separation for cerebral blood flow recovery},
  journal = {Biomedical Optics Express},
  year = {2024},
  volume = {15},
  number = {7},
  pages = {4330},
  doi = {10.1364/boe.523514}
}
Kostenlos starten →