EUVIMEDEUVIMED entdecken
Open Access

Limitations of OTF-based metrics for predicting through-focus visual acuity in pseudophakic eyes

Miguel Faria-Ribeiro iD, Noé Villemagne, Luc Joannes

Biomedical Optics Express · 01.11.2025 · 16 (11) · 4503

DOI: 10.1364/boe.575877 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 20.10.2025. Verfasst von Miguel Faria-Ribeiro und 2 weiteren Autor:innen. Beteiligte Einrichtung: Center of Physics of Porto and Minho Universities, University of Minho, Braga, Portugal. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Predicting postoperative visual acuity (VA) from optical quality metrics is essential for the evaluation and development of intraocular lenses (IOLs). Metrics based on modulation transfer function (MTF) integration are commonly used but have important limitations: they neglect the phase of the optical transfer function (OTF) and fail to account for the distribution of contrast across spatial frequencies. As a result, they may overestimate visual performance—especially under defocus—by including phase-reversed or low-frequency contrast that contributes little to visual acuity. In this study, we measured the optical profiles of five IOLs using a new metrology device (NIMO-TEMPO), simulated their polychromatic through-focus OTFs, and computed several metrics, including MTF area, OTF area, visual Strehl ratio, and a perceptually weighted real part of the OTF (wOTF). These metrics were then correlated with through-focus VA curves extracted from publicly available FDA clinical trial data. Our results show that phase-sensitive metrics, particularly those that weight frequencies according to neural relevance, mitigate some of the limitations of conventional MTF-based approaches by suppressing spurious contrast and better reflecting the spatial content most relevant to VA. These findings highlight the need for physiologically meaningful, phase-aware metrics in both research and regulatory contexts.

Autor:innen und Institutionen

  • Center of Physics of Porto and Minho Universities, University of Minho, Braga, Portugal.
  • Lambda-X Ophthalmics srl, Avenue Robert Schuman, 102, B-1400 Nivelles, Belgium.

ORCID-Profile: Miguel Faria-Ribeiro

Zitieren

APA

Faria-Ribeiro, M., Villemagne, N., & Joannes, L. (2025). Limitations of OTF-based metrics for predicting through-focus visual acuity in pseudophakic eyes. Biomedical Optics Express, 16(11), 4503. https://doi.org/10.1364/boe.575877

Vancouver

Faria-Ribeiro M, Villemagne N, Joannes L. Limitations of OTF-based metrics for predicting through-focus visual acuity in pseudophakic eyes. Biomedical Optics Express. 2025;16(11):4503. doi:10.1364/boe.575877

BibTeX
@article{FariaRibeiro2025,
  author = {Faria-Ribeiro, Miguel and Villemagne, Noé and Joannes, Luc},
  title = {Limitations of OTF-based metrics for predicting through-focus visual acuity in pseudophakic eyes},
  journal = {Biomedical Optics Express},
  year = {2025},
  volume = {16},
  number = {11},
  pages = {4503},
  doi = {10.1364/boe.575877}
}
Kostenlos starten →