Optimizing a two-layer method for hybrid diffuse correlation spectroscopy and frequency-domain diffuse optical spectroscopy cerebral measurements in adults
Neurophotonics · 23.05.2023 · 10 (02) · 1-26
DOI: 10.1117/1.nph.10.2.025008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neurophotonics, erschienen am 23.05.2023. Verfasst von Rodrigo Menezes Forti und 3 weiteren Autor:innen. Beteiligte Einrichtung: Children's Hospital of Philadelphia, Division of Neurology, Philadelphia, Pennsylvania, United States. Die Arbeit wurde bisher 17-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NINDS NIH HHS.
Abstract (Originalsprache)
SignificanceThe sensitivity to extracerebral tissues is a well-known confounder of diffuse optics. Two-layer (2L) head models can separate cerebral signals from extracerebral artifacts, but they also carry the risk of crosstalk between fitting parameters.AimWe aim to implement a constrained 2L head model for hybrid diffuse correlation spectroscopy (DCS) and frequency-domain diffuse optical spectroscopy (FD-DOS) data and to characterize errors in cerebral blood flow and tissue absorption with the proposed model.ApproachThe algorithm uses the analytical solution of a 2L cylinder and an a priori extracerebral layer thickness to fit multidistance FD-DOS (0.8 to 4 cm) and DCS (0.8 and 2.5 cm) data, assuming homogeneous tissue reduced scattering. We characterized the algorithm’s accuracy for simulated data with noise generated using a 2L slab and realistic adult head geometries and for in vitro phantom data.ResultsOur algorithm recovered the cerebral flow index with 6.3 [2.8, 13.2]% and 34 [30, 42]% (median absolute percent error [interquartile range]) for slab and head geometries, respectively. Corresponding errors in the cerebral absorption coefficient were 5.0 [3.0, 7.9]% and 4.6 [2.4, 7.2]% for the slab and head geometries and 8 [5, 12]% for our phantom experiment. Our results were minimally sensitive to second-layer scattering changes and were robust to cross-talk between fitting parameters.ConclusionsIn adults, the constrained 2L algorithm promises to improve FD-DOS/DCS accuracy compared with the conventional semi-infinite approach.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Children's Hospital of Philadelphia, Division of Neurology, Philadelphia, Pennsylvania, United States.
- University of Campinas, Institute of Physics, Campinas, Brazil.
- Brazilian Institute of Neuroscience and Neurotechnology, Campinas, Brazil.
ORCID-Profile: Rodrigo Menezes Forti, Giovani Grisotti Martins, Wesley Boehs Baker, Rickson C Mesquita
Förderung
- NINDS NIH HHS
Zitieren
APA
Forti, R. M., Martins, G. G., Baker, W. B., & Mesquita, R. C. (2023). Optimizing a two-layer method for hybrid diffuse correlation spectroscopy and frequency-domain diffuse optical spectroscopy cerebral measurements in adults. Neurophotonics, 10(02), 1-26. https://doi.org/10.1117/1.nph.10.2.025008
Vancouver
Forti RM, Martins GG, Baker WB, Mesquita RC. Optimizing a two-layer method for hybrid diffuse correlation spectroscopy and frequency-domain diffuse optical spectroscopy cerebral measurements in adults. Neurophotonics. 2023;10(02):1-26. doi:10.1117/1.nph.10.2.025008
BibTeX
@article{Forti2023,
author = {Forti, Rodrigo Menezes and Martins, Giovani Grisotti and Baker, Wesley Boehs and Mesquita, Rickson C},
title = {Optimizing a two-layer method for hybrid diffuse correlation spectroscopy and frequency-domain diffuse optical spectroscopy cerebral measurements in adults},
journal = {Neurophotonics},
year = {2023},
volume = {10},
number = {02},
pages = {1--26},
doi = {10.1117/1.nph.10.2.025008}
}
EUVIMED