EUVIMEDEUVIMED entdecken
Open Access

Multicolor fluorescence microscopy for surgical guidance using a chip-scale imager with a low-NA fiber optic plate and a multi-bandpass interference filter

Micah Roschelle iD, Rozhan Rabbani, Efthymios Papageorgiou, Hui Zhang, Matthew Cooperberg, Bradley A Stohr, Ali Niknejad, Mekhail Anwar

Biomedical Optics Express · 01.03.2024 · 15 (3) · 1761

DOI: 10.1364/boe.509235 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 20.02.2024. Verfasst von Micah Roschelle und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720, USA. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDCR NIH HHS, John V. Carbone Jr. Pancreas Cancer Research Memorial Fund, National Institute of Dental and Craniofacial Research.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In curative-intent cancer surgery, intraoperative fluorescence imaging of both diseased and healthy tissue can help to ensure the successful removal of all gross and microscopic diseases with minimal damage to neighboring critical structures, such as nerves. Current fluorescence-guided surgery (FGS) systems, however, rely on bulky and rigid optics that incur performance-limiting trade-offs between sensitivity and maneuverability. Moreover, many FGS systems are incapable of multiplexed imaging. As a result, clinical FGS is currently limited to millimeter-scale detection of a single fluorescent target. Here, we present a scalable, lens-less fluorescence imaging chip, VISION, capable of sensitive and multiplexed detection within a compact form factor. Central to VISION is a novel optical frontend design combining a low-numerical-aperture fiber optic plate (LNA-FOP) and a multi-bandpass interference filter, which is affixed to a custom CMOS image sensor. The LNA-FOP acts as a planar collimator to improve resolution and compensate for the angle-sensitivity of the interference filter, enabling high-resolution and multiplexed fluorescence imaging without lenses. We show VISION is capable of detecting tumor foci of less than 100 cells at near video framerates and, as proof of principle, can simultaneously visualize both tumors and nerves in ex vivo prostate tissue.

Autor:innen und Institutionen

  • Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720, USA.
  • micah.roschelle@berkeley.edu.
  • Department of Radiation Oncology, University of California, San Francisco, California 94158, USA.
  • Department of Urology, University of California, San Francisco, California 94158, USA.
  • Department of Pathology, University of California, San Francisco, California 94158, USA.
  • Mekhail.Anwar@ucsf.edu.

ORCID-Profile: Micah Roschelle

Förderung

  • NIDCR NIH HHS
  • John V. Carbone Jr. Pancreas Cancer Research Memorial Fund
  • National Institute of Dental and Craniofacial Research

Zitieren

APA

Roschelle, M., Rabbani, R., Papageorgiou, E., Zhang, H., Cooperberg, M., Stohr, B. A., Niknejad, A., & Anwar, M. (2024). Multicolor fluorescence microscopy for surgical guidance using a chip-scale imager with a low-NA fiber optic plate and a multi-bandpass interference filter. Biomedical Optics Express, 15(3), 1761. https://doi.org/10.1364/boe.509235

Vancouver

Roschelle M, Rabbani R, Papageorgiou E, Zhang H, Cooperberg M, Stohr BA, et al. Multicolor fluorescence microscopy for surgical guidance using a chip-scale imager with a low-NA fiber optic plate and a multi-bandpass interference filter. Biomedical Optics Express. 2024;15(3):1761. doi:10.1364/boe.509235

BibTeX
@article{Roschelle2024,
  author = {Roschelle, Micah and Rabbani, Rozhan and Papageorgiou, Efthymios and Zhang, Hui and Cooperberg, Matthew and Stohr, Bradley A and Niknejad, Ali and Anwar, Mekhail},
  title = {Multicolor fluorescence microscopy for surgical guidance using a chip-scale imager with a low-NA fiber optic plate and a multi-bandpass interference filter},
  journal = {Biomedical Optics Express},
  year = {2024},
  volume = {15},
  number = {3},
  pages = {1761},
  doi = {10.1364/boe.509235}
}
Kostenlos starten →