EUVIMEDEUVIMED entdecken
Crossref

CRSS: Consistency-regularized semi-supervised spectral unmixing for multicolor fluorescence microscopy images

Qingyang Lan, Guiping Zhuang, Chang Wen, Shihuan Luo, Hangning Liu, Min Hu, Zhengfei Zhuang

Biomedical Signal Processing and Control · 2027-02 · 130 · 111560

DOI: 10.1016/j.bspc.2026.111560 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Signal Processing and Control, 2027-02. Verfasst von Qingyang Lan und 6 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guangdong Provincial Natural Science Foundation, Guangdong Special Support Plan.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multicolor fluorescence microscopy is a cornerstone of biomedical research, enabling simultaneous visualization of multiple subcellular targets. However, inherent spectral overlap between fluorophores causes pervasive detection-channel crosstalk, which distorts quantitative intensity measurements, generates false co-localization signals, and severely limits multiplexing capacity. Traditional unmixing methods rely on pre-calibrated reference spectra and lack adaptability to variable experimental conditions, while deep learning approaches require costly fully labeled fluorescence datasets. We propose CRSS, a semi-supervised blind spectral unmixing method that jointly models spectral-spatial features via the Global-Local Spectral Attention module, adaptively fuses channel-pair features via the Dynamic Feature Fusion module, and imposes bidirectional consistency constraints on unlabeled data using multiple Gaussian perturbations. The method leverages limited labeled and abundant unlabeled data through dual-path synergistic training combining supervised loss, unsupervised reconstruction loss, and multi-perturbation consistency loss. Trained on 344 U-2 OS images with only 9.7 % labeled data (33 samples), CRSS achieves SSIM = 0.972 (just 1.06 % below full supervision) and PSNR = 36.43 dB. It reduces MSE by 23.8 % on cross-domain mouse brain data and generalizes well to BPAE cells. The experimental results show that CRSS achieves a significant improvement in data utilization efficiency through the consistency regularization strategy, and achieves unmixing accuracy close to that of fully supervised methods with only 9.7 % labeled data. This work addresses the high annotation cost challenge for fluorescence spectral data, eliminates the need for laborious spectral calibration, and provides a robust, easy-to-deploy unmixing solution for routine multicolor imaging in cell biology and neuroscience research.

Förderung

  • National Natural Science Foundation of China
  • Guangdong Provincial Natural Science Foundation
  • Guangdong Special Support Plan
  • Special Project for Research and Development in Key areas of Guangdong Province

Zitieren

APA

Lan, Q., Zhuang, G., Wen, C., Luo, S., Liu, H., Hu, M., & Zhuang, Z. (2027). CRSS: Consistency-regularized semi-supervised spectral unmixing for multicolor fluorescence microscopy images. Biomedical Signal Processing and Control, 130, 111560. https://doi.org/10.1016/j.bspc.2026.111560

Vancouver

Lan Q, Zhuang G, Wen C, Luo S, Liu H, Hu M, et al. CRSS: Consistency-regularized semi-supervised spectral unmixing for multicolor fluorescence microscopy images. Biomedical Signal Processing and Control. 2027;130:111560. doi:10.1016/j.bspc.2026.111560

BibTeX
@article{Lan2027,
  author = {Lan, Qingyang and Zhuang, Guiping and Wen, Chang and Luo, Shihuan and Liu, Hangning and Hu, Min and Zhuang, Zhengfei},
  title = {CRSS: Consistency-regularized semi-supervised spectral unmixing for multicolor fluorescence microscopy images},
  journal = {Biomedical Signal Processing and Control},
  year = {2027},
  volume = {130},
  pages = {111560},
  doi = {10.1016/j.bspc.2026.111560}
}
Kostenlos starten →