Pareto-based parameter screening for mid- and high-spatial-frequency errors in CO 2 laser beam figuring of fused silica
Applied Optics · 20.11.2026 · 65 (33) · 11657
DOI: 10.1364/ao.607221 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Optics, online erschienen am 10.11.2026. Verfasst von Moustafa Ibrahim und 5 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Forschung, Technologie und Raumfahrt, University of Kassel.
Abstract (Originalsprache)
Laser beam figuring (LBF) with microsecond-pulsed CO 2 laser radiation enables nanometer-precision material removal on fused silica for deterministic surface figure correction in high-performance optical fabrication. This work presents a framework combining experimentally measured single-pulse craters with a geometric line-synthesis model to construct geometric reference topographies under a pulse-independent-kernel assumption as a function of pulse duration t p and pulse spacing d x . A Pareto-dominance analysis of 60 parameter combinations quantifies the trade-off between mid-spatial-frequency (MSFE) and high-spatial-frequency (HSFE) roughness over a bounded synthesis window, where it arises from the line terminations. Within the investigated parameter space, equal weighting selects t p =90µs and d x =5−10µm for a single pass ( R q MSFE =6.17−6.40nm, R q HSFE =1.06−1.34nm). A limited experimental comparison at two pulse spacings shows substantial deviations from the geometric reference model at high overlap. At equal weighting, the measured lines favor the larger of the two pitches. A transient thermal simulation indicates interpulse heat accumulation. The reported optimum is therefore a property of the defined synthesis construction rather than a validated prediction of fabricated surfaces.
Förderung
- Bundesministerium für Forschung, Technologie und Raumfahrt
- University of Kassel
Zitieren
APA
Ibrahim, M., Uluz, E., Mansour, N., Willenborg, E., Haefner, C., & Dahlhaus, D. (2026). Pareto-based parameter screening for mid- and high-spatial-frequency errors in CO 2 laser beam figuring of fused silica. Applied Optics, 65(33), 11657. https://doi.org/10.1364/ao.607221
Vancouver
Ibrahim M, Uluz E, Mansour N, Willenborg E, Haefner C, Dahlhaus D. Pareto-based parameter screening for mid- and high-spatial-frequency errors in CO 2 laser beam figuring of fused silica. Applied Optics. 2026;65(33):11657. doi:10.1364/ao.607221
BibTeX
@article{Ibrahim2026,
author = {Ibrahim, Moustafa and Uluz, Emrah and Mansour, Nour and Willenborg, Edgar and Haefner, Constantin and Dahlhaus, Dirk},
title = {Pareto-based parameter screening for mid- and high-spatial-frequency errors in CO 2 laser beam figuring of fused silica},
journal = {Applied Optics},
year = {2026},
volume = {65},
number = {33},
pages = {11657},
doi = {10.1364/ao.607221}
}
EUVIMED