EUVIMEDEUVIMED entdecken
Crossref

Multisensor fusion-based laser scanning method for precision measurement of specially shaped deep holes

Da Xie, Yu Deng, Linzhe Deng, Chunyang Wang, Chuiyang Yu, Xuelian Liu, Huan Wu

Applied Optics · 10.07.2026 · 65 (20) · 6717

DOI: 10.1364/ao.604753 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Optics, online erschienen am 01.07.2026. Verfasst von Da Xie und 6 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Specially shaped deep-hole components, such as gun barrels, long shaft sleeves, and complex tubing, are widely used in aerospace and heavy machinery manufacturing. Their large length-to-diameter ratios, non-circular internal cross sections, and severely confined inspection space make it difficult for conventional contact measurement to simultaneously satisfy efficiency and full-field coverage requirements, while existing optical methods suffer from long-stroke error accumulation. This paper proposes a non-contact precision measurement method based on endoscopic line-laser scanning combined with principal component analysis (PCA). An endoscopic measurement system that integrates a direct laser-triangulation probe and a position-sensitive-detector (PSD) pose-feedback module is first constructed, and the corresponding optical and pose-coordinate mapping models are established, with a fully decoupled four-degree-of-freedom pose solution. An incremental point-cloud stitching algorithm that fuses a motion-direction-vector constraint with real-time pose compensation is then developed; it suppresses the stitching error introduced by roll, pitch, and yaw fluctuations of the in-bore probe and enables high-accuracy three-dimensional reconstruction of the deep-hole profile. For geometric parameter evaluation, the initial-value sensitivity of the conventional least-squares method is mitigated by extracting the principal directions of the point cloud through PCA and using them as a robust, near-optimal initial value for minimum-zone evaluation; a non-uniform rational B-spline (NURBS) curve model then computes line-profile error and spatial generatrix straightness. On a representative deep-hole specimen, the measurement error—defined consistently as |measured−CMM reference|—is below 0.005 mm for line profile, and below 0.009 mm for straightness, with a measured repeatability (1 σ ) of ≈1.0µm and ≈1.5µm, respectively, while the per-section computation is more than 50% faster than conventional iterative algorithms. The method provides an effective route for on-line precision inspection of complex deep-hole inner profiles.

Zitieren

APA

Xie, D., Deng, Y., Deng, L., Wang, C., Yu, C., Liu, X., & Wu, H. (2026). Multisensor fusion-based laser scanning method for precision measurement of specially shaped deep holes. Applied Optics, 65(20), 6717. https://doi.org/10.1364/ao.604753

Vancouver

Xie D, Deng Y, Deng L, Wang C, Yu C, Liu X, et al. Multisensor fusion-based laser scanning method for precision measurement of specially shaped deep holes. Applied Optics. 2026;65(20):6717. doi:10.1364/ao.604753

BibTeX
@article{Xie2026,
  author = {Xie, Da and Deng, Yu and Deng, Linzhe and Wang, Chunyang and Yu, Chuiyang and Liu, Xuelian and Wu, Huan},
  title = {Multisensor fusion-based laser scanning method for precision measurement of specially shaped deep holes},
  journal = {Applied Optics},
  year = {2026},
  volume = {65},
  number = {20},
  pages = {6717},
  doi = {10.1364/ao.604753}
}
Kostenlos starten →