EUVIMEDEUVIMED entdecken
Crossref

The First Nozzle-Mounted Compton Camera Prompt Gamma Imaging System for In Vivo Proton Therapy Dose Verification

Farshad Safavi, S Peterson, Sina Mossahebi, Ananta Raj Chalise, V. Sharma, Matthias K. Gobbert, J Polf, Lei Ren

Digital Repository at the University of Maryland (University of Maryland College Park) · 02.06.2026

DOI: 10.13016/m2uli0-c6g2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Digital Repository at the University of Maryland (University of Maryland College Park), erschienen am 02.06.2026. Verfasst von Farshad Safavi und 7 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents the first clinical integration and experimental demonstration of a nozzle-mounted Compton camera prompt gamma imaging (PGI) system for in vivo proton range verification. Four position-sensitive solid-state Compton camera modules, each containing four cadmium zinc telluride (CdZnTe) detector crystals, were integrated into a modified range shifter mounted directly on the treatment nozzle of a clinical proton therapy gantry. This compact fixed-geometry configuration maintained alignment with the proton beam axis throughout irradiation and enabled stable synchronized data acquisition during pencil-beam scanning delivery. The system was evaluated under realistic clinical proton beam delivery conditions using single-energy and spread-out Bragg peak (SOBP) irradiations at gantry angles of 90° and 270°, delivered doses of 2 Gy and 7.5 Gy, and controlled distal range shifts of up to 10 mm. Prompt gamma events were reconstructed into three-dimensional emission distributions using a physics-based Compton scatter reconstruction framework. The system operated reliably during all irradiations and produced reproducible prompt-gamma localization across repeated measurements. Reconstructed emission distributions remained geometrically consistent across gantry angles and demonstrated sensitivity to controlled distal range perturbations, with measurable upstream shifts of the emission hotspot corresponding to reduced proton penetration depth. These results demonstrate the feasibility of a clinically integrated nozzle-mounted quad-camera Compton PGI system for detecting millimeter-scale proton range variations during beam delivery and represent an important step toward clinically deployable prompt gamma-based in vivo treatment verification in proton therapy.

Schlagwörter

prompt gamma imagingCompton cameraproton therapyin vivo dose verificationproton range verificationCdZnTe detectorsrange shifterspread-out Bragg peakpencil beam scanning

Zitieren

APA

Safavi, F., Peterson, S., Mossahebi, S., Chalise, A. R., Sharma, V., Gobbert, M. K., Polf, J., & Ren, L. (2026). The First Nozzle-Mounted Compton Camera Prompt Gamma Imaging System for In Vivo Proton Therapy Dose Verification. Digital Repository at the University of Maryland (University of Maryland College Park). https://doi.org/10.13016/m2uli0-c6g2

Vancouver

Safavi F, Peterson S, Mossahebi S, Chalise AR, Sharma V, Gobbert MK, et al. The First Nozzle-Mounted Compton Camera Prompt Gamma Imaging System for In Vivo Proton Therapy Dose Verification. Digital Repository at the University of Maryland (University of Maryland College Park). 2026. doi:10.13016/m2uli0-c6g2

BibTeX
@article{Safavi2026,
  author = {Safavi, Farshad and Peterson, S and Mossahebi, Sina and Chalise, Ananta Raj and Sharma, V. and Gobbert, Matthias K. and Polf, J and Ren, Lei},
  title = {The First Nozzle-Mounted Compton Camera Prompt Gamma Imaging System for In Vivo Proton Therapy Dose Verification},
  journal = {Digital Repository at the University of Maryland (University of Maryland College Park)},
  year = {2026},
  doi = {10.13016/m2uli0-c6g2}
}
Kostenlos starten →