Modeling prompt gamma (PG) emission, detection and imaging in real patient anatomy using a novel Compton camera for dose verification in proton therapy
Physics in Medicine & Biology · 22.06.2025 · 70 (12) · 125004
DOI: 10.1088/1361-6560/addf0d ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 10.06.2025. Verfasst von V R Sharma und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, School of Medicine, University of Maryland, Baltimore, MD 21201, United States of America. Hauptthemen laut MEDLINE: Proton Therapy, Gamma Rays, Radiation Dosage, Gamma Cameras. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIBIB NIH HHS, All of Us Research Program.
Abstract (Originalsprache)
Objective . Prompt gamma (PG) imaging is a promising modality for proton dose verification. Currently, there is a lack of effective tools to investigate the entire PG imaging process in patient anatomy, from PG emission to camera detection and image reconstruction, to evaluate and optimize its efficacy for dose verification in proton therapy. Approach . To address this gap, we developed a Monte-Carlo package, POLARIS J Monte Carlo (PJ-MC), that simulates the entire PG emission and imaging workflow in patient anatomy. We utilized Geant4 classes and G4-ancillary tools, employing the DCMTK external tool with G4PhantomParameterisation to convert patient CT data into voxelized geometries. Proton beams were modeled based on medical physics commissioning data. A novel two-stage POLARIS-J3 Compton-Camera was simulated under the patient couch for recording total, double, and triple scattered PG signals. Proton maximum range calculations from the PJ-MC are compared with dose calculations from a clinical treatment planning system. The detected PG signals data in the simulation were used to reconstruct PG images using Kernel- Weighted-Back-Projection algorithm. Main results . Analysis of gamma energy distribution showed a decay pattern with clear emission lines from nuclear reactions involving oxygen, carbon, nitrogen, and calcium. Neutron-induced reactions contribute significantly less-by an order of magnitude-compared to proton-induced reactions in various tissues. Mean absolute percentage error analysis showed that PG range verification was more stable when considering the range at 80 % or 50 % of D max , as opposed to the range at the D max , where energy gating slightly improves accuracy but may reduce localization due to photon loss. Results showed that patient anatomy can impact the location of hot spot in the PG images, affecting its accuracy for localizing Bragg peak. Significance . In summary, our simulation package provides additional insights into PG emission and imaging in patient anatomy and serves as a robust tool for evaluating and optimizing PG imaging, enhancing its precision for dose verification in proton therapy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, School of Medicine, University of Maryland, Baltimore, MD 21201, United States of America.
- Department of Radiation Oncology, Stanford University, Stanford, CA 94304, United States of America.
- Maryland Proton Treatment Center, Baltimore, MD, United States of America.
- Department of Mathematics and Statistics, University of Maryland Baltimore County, Baltimore, MD, United States of America.
- Department of Physics, University of Cape Town, Rondebosch 7700, South Africa.
- M3D, Ann Arbor, MI 48108, United States of America.
ORCID-Profile: V R Sharma, M K Gobbert, L Ren
Förderung
- NCI NIH HHS
- NIBIB NIH HHS
- All of Us Research Program
Zitieren
APA
Sharma, V. R., Jiang, Z., Mossahebi, S., Shakeri, E., Chalise, A., Gobbert, M. K., Peterson, S. W., Polf, J. C., & Ren, L. (2025). Modeling prompt gamma (PG) emission, detection and imaging in real patient anatomy using a novel Compton camera for dose verification in proton therapy. Physics in Medicine & Biology, 70(12), 125004. https://doi.org/10.1088/1361-6560/addf0d
Vancouver
Sharma VR, Jiang Z, Mossahebi S, Shakeri E, Chalise A, Gobbert MK, et al. Modeling prompt gamma (PG) emission, detection and imaging in real patient anatomy using a novel Compton camera for dose verification in proton therapy. Physics in Medicine & Biology. 2025;70(12):125004. doi:10.1088/1361-6560/addf0d
BibTeX
@article{Sharma2025,
author = {Sharma, V R and Jiang, Z and Mossahebi, S and Shakeri, E and Chalise, A and Gobbert, M K and Peterson, S W and Polf, J C and Ren, L},
title = {Modeling prompt gamma (PG) emission, detection and imaging in real patient anatomy using a novel Compton camera for dose verification in proton therapy},
journal = {Physics in Medicine & Biology},
year = {2025},
volume = {70},
number = {12},
pages = {125004},
doi = {10.1088/1361-6560/addf0d}
}