EUVIMEDEUVIMED entdecken
Crossref

Performance Evaluation of a Low-Cost Air Quality Monitoring Device under Tropical Urban Conditions in Kuala Terengganu, Malaysia

Muhammad Syakirul Naim Mat Rifin, Aimi Nursyahirah Ahmad, Amalina Abu Mansor, Zamzam Tuah Ahmad Ramly, Samsuri Abdullah

Natural and Life Sciences Communications · 09.04.2026 · 25 (3)

DOI: 10.12982/nlsc.2026.061 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Natural and Life Sciences Communications, online erschienen am 09.04.2026. Verfasst von Muhammad Syakirul Naim Mat Rifin und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluates the performance of a low-cost air quality monitoring device, the Oizom Polludrone, for sustainable air quality assessment in Kuala Terengganu, Malaysia. The objectives were to analyse temporal variations of major air pollutants and meteorological parameters, examine relationships between pollutants and meteorological factors, and assess the reliability of the low-cost device through comparison with data from the Department of Environment (DOE) station. Hourly data on particulate matter (PM1, PM2.5, and PM10), gaseous pollutants (CO, NO2, SO2, and O3), and meteorological variables (temperature, relative humidity, wind speed, ultraviolet radiation, and atmospheric pressure) were collected over a three-month monitoring period. Results showed that particulate matter concentrations were consistently higher than gaseous pollutants, identifying particulate pollution as a dominant air quality concern in the study area. Strong positive correlations were observed between PM2.5 and PM10 (r = 0.997) as well as PM1 (r = 0.995), indicating common emission sources and similar atmospheric behaviour. Meteorological parameters, particularly wind speed and relative humidity, were found to influence pollutant dispersion and accumulation. Comparison with DOE reference data yielded a moderate level of agreement for PM2.5 measurements (R2 = 0.3549), indicating that the low-cost device captured general pollution trends despite some variability. Overall, the findings demonstrate that the Oizom Polludrone is a reliable and cost-effective tool for supplementary and indicative air quality monitoring in tropical urban environments such as Kuala Terengganu. While not intended to replace regulatory-grade monitoring stations, its application can enhance spatial and temporal air quality coverage, supporting sustainable urban air quality management.

Zitieren

APA

Rifin, M. S. N. M., Ahmad, A. N., Mansor, A. A., Ramly, Z. T. A., & Abdullah, S. (2026). Performance Evaluation of a Low-Cost Air Quality Monitoring Device under Tropical Urban Conditions in Kuala Terengganu, Malaysia. Natural and Life Sciences Communications, 25(3). https://doi.org/10.12982/nlsc.2026.061

Vancouver

Rifin MSNM, Ahmad AN, Mansor AA, Ramly ZTA, Abdullah S. Performance Evaluation of a Low-Cost Air Quality Monitoring Device under Tropical Urban Conditions in Kuala Terengganu, Malaysia. Natural and Life Sciences Communications. 2026;25(3). doi:10.12982/nlsc.2026.061

BibTeX
@article{Rifin2026,
  author = {Rifin, Muhammad Syakirul Naim Mat and Ahmad, Aimi Nursyahirah and Mansor, Amalina Abu and Ramly, Zamzam Tuah Ahmad and Abdullah, Samsuri},
  title = {Performance Evaluation of a Low-Cost Air Quality Monitoring Device under Tropical Urban Conditions in Kuala Terengganu, Malaysia},
  journal = {Natural and Life Sciences Communications},
  year = {2026},
  volume = {25},
  number = {3},
  doi = {10.12982/nlsc.2026.061}
}
Kostenlos starten →