Field Calibration of a Low-Cost Air Quality Monitoring Device in an Urban Background Site Using Machine Learning Models
Atmosphere · 13.02.2023 · 14 (2) · 368
DOI: 10.3390/atmos14020368 ↗Kurz gefasst
Fachartikel in der Zeitschrift Atmosphere, online erschienen am 13.02.2023. Verfasst von Ioannis D. Apostolopoulos und 2 weiteren Autor:innen. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EU Horizon Europe, project SynAirG.
Abstract (Originalsprache)
Field calibration of low-cost air quality (AQ) monitoring sensors is essential for their successful operation. Low-cost sensors often exhibit non-linear responses to air pollutants and their signals may be affected by the presence of multiple compounds making their calibration challenging. We investigate different approaches for the field calibration of an AQ monitoring device named ENSENSIA, developed in the Institute of Chemical Engineering Sciences in Greece. The present study focuses on the measurements of two of the most important pollutants measured by ENSENSIA: NO2 and O3. The measurement site is located in the center of Patras, the third biggest city in Greece. Reference instrumentation used for regulatory purposes by the Region of Western Greece was used as the evaluation standard. The sensors were installed for two years at the same locations. Measurements from the first year (2021) from seven ENSENSIA sensors (NO2, NO, O3, CO, PM2.5, temperature and relative humidity) were used to train several Machine Learning (ML) and Deep Learning (DL) algorithms. The resulting calibration algorithms were assessed using data from the second year (2022). The Random Forest algorithm exhibited the best performance in correcting O3 and NO2. For NO2 the mean error was reduced from 9.4 ppb to 3 ppb, whilst R2 improved from 0.22 to 0.86. Similar results were obtained for O3, wherein the mean error was reduced from 13 to 4.3 ppb and R2 increased from 0.52 to 0.69. The Long-Short Term Memory Network (LSTM) also showed good performance in correcting the measurements of the two pollutants.
Förderung
- EU Horizon Europe, project SynAirG
Zitieren
APA
Apostolopoulos, I. D., Fouskas, G., & Pandis, S. N. (2023). Field Calibration of a Low-Cost Air Quality Monitoring Device in an Urban Background Site Using Machine Learning Models. Atmosphere, 14(2), 368. https://doi.org/10.3390/atmos14020368
Vancouver
Apostolopoulos ID, Fouskas G, Pandis SN. Field Calibration of a Low-Cost Air Quality Monitoring Device in an Urban Background Site Using Machine Learning Models. Atmosphere. 2023;14(2):368. doi:10.3390/atmos14020368
BibTeX
@article{Apostolopoulos2023,
author = {Apostolopoulos, Ioannis D. and Fouskas, George and Pandis, Spyros N.},
title = {Field Calibration of a Low-Cost Air Quality Monitoring Device in an Urban Background Site Using Machine Learning Models},
journal = {Atmosphere},
year = {2023},
volume = {14},
number = {2},
pages = {368},
doi = {10.3390/atmos14020368}
}
EUVIMED