EUVIMEDEUVIMED entdecken
QuerschnittstudieOpen Access · CC BY-NC 3.0

Computed tomography plane reformatting to reduce projection error in measuring Pauwels angle of femoral neck fractures: a cross-sectional study

Gyu Min Kong, Jae-Young Lim, Se-Lin Jeong, Gu-Hee Jung

Journal of Musculoskeletal Trauma · 2026

DOI: 10.12671/jmt.2025.00038 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift Journal of Musculoskeletal Trauma, 2026. Verfasst von Gyu Min Kong und 3 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to assess fracture verticality in both coronal and axial planes after eliminating projection error in femoral neck fractures among non-older adults, and to demonstrate its clinical utility using computed tomography (CT)-based modeling at actual size.

Methods

This retrospective observational study enrolled 57 patients (30 males and 27 females), aged 20–65 years, with displaced femoral neck fractures. Based on CT images, an actual-size fracture model was constructed. The CT scanning plane was reformatted with the neck-shaft fragment realigned vertically to the ground and parallel to the femoral neck axis. Three consecutive images were used to generate coronal reformats at the centerline and posterior border to measure central and posterior coronal plane verticality as Pauwels’ angle (PA). The central image of the reformatted axial plane was used to assess axial plane verticality. Differences in verticality were analyzed using analysis of variance.

Results

Three coronal morphology types were identified: linear (n=30), concave (n=25), and convex (n=2). Two axial morphology types were observed: cephalad (n=35) and trochanteric (n=22). The mean central PA, posterior PA, and axial verticality were 55.43°±13.79°, 51.44°±11.13°, and 85.74°±18.41°, respectively. Only the central PA showed a significant difference (P

Zitieren

APA

Kong, G. M., Lim, J., Jeong, S., & Jung, G. (2026). Computed tomography plane reformatting to reduce projection error in measuring Pauwels angle of femoral neck fractures: a cross-sectional study. Journal of Musculoskeletal Trauma. https://doi.org/10.12671/jmt.2025.00038

Vancouver

Kong GM, Lim J, Jeong S, Jung G. Computed tomography plane reformatting to reduce projection error in measuring Pauwels angle of femoral neck fractures: a cross-sectional study. Journal of Musculoskeletal Trauma. 2026. doi:10.12671/jmt.2025.00038

BibTeX
@article{Kong2026,
  author = {Kong, Gyu Min and Lim, Jae-Young and Jeong, Se-Lin and Jung, Gu-Hee},
  title = {Computed tomography plane reformatting to reduce projection error in measuring Pauwels angle of femoral neck fractures: a cross-sectional study},
  journal = {Journal of Musculoskeletal Trauma},
  year = {2026},
  doi = {10.12671/jmt.2025.00038}
}