EUVIMEDEUVIMED entdecken
Crossref

Good outcome can be achieved by femoral neck system with a supplementary Pauwels screw for unstable Pauwels type III femoral neck fractures in less than 65 years old adults

Chun Yu Wu, Chun Yu Chen, Kai Cheng Lin

European Journal of Orthopaedic Surgery & Traumatology · 14.11.2026 · 37 (1)

DOI: 10.1007/s00590-026-05031-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, online erschienen am 14.11.2026. Verfasst von Chun Yu Wu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan. Hauptthemen laut MEDLINE: Femoral Neck Fractures, Bone Screws, Fracture Fixation, Internal. Die Arbeit nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pauwels type III femoral neck fractures in adults younger than 65 years are usually caused by high-energy trauma, are loaded predominantly in vertical shear, and carry high rates of nonunion, fixation failure and avascular necrosis (AVN). The Femoral Neck System (FNS) provides angular and rotational stability, but in this pattern, particularly with posteromedial comminution, standalone FNS is still followed by substantial femoral neck shortening, which is associated with inferior hip function. We therefore added a supplementary Pauwels screw placed approximately perpendicular to the fracture line. This preliminary case series describes the technique and its early outcomes, with union with no more than mild (≤ 5 mm) shortening as the primary outcome.

Methods

Since March 2024, we have used FNS with an additional Pauwels screw for unstable Pauwels type III femoral neck fractures in patients younger than 65 years. Closed reduction was performed on a fracture table, and limited open reduction was added when required. After anatomical or near-anatomical reduction, a standard FNS was implanted first, and a single supplementary cannulated screw was then inserted from the middle-to-lower greater trochanter towards the central-inferior femoral head, crossing the fracture line as close to 90° as possible. Patients were kept non-weight-bearing for at least 6 weeks. Femoral neck shortening, the primary outcome, was graded as none or mild (≤ 5 mm), moderate (5–10 mm) or severe (> 10 mm). Construct-related mechanical complications, comprising FNS implant failure, loss of reduction and back-out of the Pauwels screw, were recorded, and hip function was assessed with the Harris Hip Score (HHS).

Results

All ten fractures were displaced Pauwels type III fractures (Garden type III, n = 1; Garden type IV, n = 9). Mean age was 42.3 ± 12.3 years and mean follow-up 18.0 ± 5.3 months. Mean operative time was 102.11 ± 42.20 min, blood loss 111.00 ± 74.75 mL and hospital stay 4.10 ± 1.91 days. Three patients had a comminuted posteromedial cortex on preoperative CT. All ten fractures united, at a mean of 118.44 ± 54.63 days. Mean femoral neck shortening was 2.87 ± 3.65 mm; the primary outcome, union with no more than mild shortening, was achieved in 7 of 10 patients (95% CI 35–93%), and two had moderate and one severe shortening. Construct-related mechanical complications occurred in 2 of 10 patients — back-out of the Pauwels screw in both, with 7° of varus collapse in one — and no FNS implant failure occurred; both backed-out screws were removed after union. AVN developed in 1 of 10 patients, and no patient required conversion to arthroplasty. The mean HHS was 93.08 ± 6.63 at the latest clinic follow-up and 90.61 ± 6.61 at a telephone interview, with excellent-to-good results in 9 of 10 patients at both assessments.

Conclusion

In this preliminary series, FNS supplemented with a perpendicular Pauwels screw was technically feasible; all fractures united and 7 of 10 healed with no more than mild (≤ 5 mm) shortening, although varus collapse occurred in one patient, AVN in one and screw back-out in two. Without a control group these results cannot be attributed to the supplementary screw, and comparative studies with longer follow-up are needed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Femoral Neck FracturesBone ScrewsFracture Fixation, InternalHumansFemaleMaleTreatment OutcomeAdultMiddle AgedProximal Femoral FracturesFracture Healing

Stichwörter der Autor:innen

Femoral Neck SystemFemoral neck fractureInternal fixationPauwels type IIISupplementary screwYoung adults

Autor:innen und Institutionen

  • Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan.
  • Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan. orthokcl@gmail.com.

Zitieren

APA

Wu, C. Y., Chen, C. Y., & Lin, K. C. (2026). Good outcome can be achieved by femoral neck system with a supplementary Pauwels screw for unstable Pauwels type III femoral neck fractures in less than 65 years old adults. European Journal of Orthopaedic Surgery & Traumatology, 37(1). https://doi.org/10.1007/s00590-026-05031-2

Vancouver

Wu CY, Chen CY, Lin KC. Good outcome can be achieved by femoral neck system with a supplementary Pauwels screw for unstable Pauwels type III femoral neck fractures in less than 65 years old adults. European Journal of Orthopaedic Surgery & Traumatology. 2026;37(1). doi:10.1007/s00590-026-05031-2

BibTeX
@article{Wu2026,
  author = {Wu, Chun Yu and Chen, Chun Yu and Lin, Kai Cheng},
  title = {Good outcome can be achieved by femoral neck system with a supplementary Pauwels screw for unstable Pauwels type III femoral neck fractures in less than 65 years old adults},
  journal = {European Journal of Orthopaedic Surgery & Traumatology},
  year = {2026},
  volume = {37},
  number = {1},
  doi = {10.1007/s00590-026-05031-2}
}
Kostenlos starten →