EUVIMEDEUVIMED entdecken
Open Access

The dosimetric underpinning of bladder filling criteria for prostate image-guided volumetric modulated arc therapy

Vickie Kong iD, Jennifer Dang, Vanessa Wan, Tara Rosewall

The British Journal of Radiology · 01.06.2023 · 96 (1146)

DOI: 10.1259/bjr.20230020 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The British Journal of Radiology, erschienen am 01.06.2023. Verfasst von Vickie Kong und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Prostatic Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Repeated CT simulation imaging is common at our institution due to failure to achieve acceptable bladder filling in patients undergoing prostate radiotherapy. There is operational value in re-assessing the validity of the bladder filling assessment criteria by comparing the quality of two plans optimized based on either an “Accepted” or “Rejected” bladder status.

Methods

Twenty prostate patients with repeated CT simulation imaging were included. For each patient, a VMAT plan created using the “Rejected” bladder was compared with the “Accepted” bladder plan. Then, delivered dose to bladder was estimated using ≥4 CBCTs to measure number of fractions with major bladderdose violation (>5% difference) for both plans. Bladder heights of fractions without major bladder dose violations were compared to those with a violation to determine a threshold height for bladder filling acceptability.

Results

Using the “Accepted” bladder plans for treatment resulted in 30/175 fractions with major dose violations. These 30 bladders were significantly shorter than those without major violation (mean 28 vs 43mm, p < 0.05). The “Rejected” bladder plans delivered a lower dose to the bladder by ≥5% than the ‘“Accepted” bladder plans in 59% of fractions, and the number of fractions with major dose violations was 17.

Conclusions

Using a shorter bladder for plan optimization resulted in better bladder sparing during treatment and improved compliance to protocol specific bladder dose constraints. A bladder height range of 20–40 mm measured between the bladder dome and the superior aspect of the symphysis pubis is recommended for prostate radiotherapy requiring a full bladder protocol. Advances in knowledge: Using real patient data from simulation and treatment, this study established a range of bladder height that can be measured easily in a clinical setting for assessing adequacy of bladder filling for prostate radiotherapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Intensity-ModulatedProstatic NeoplasmsMaleHumansProstateUrinary BladderRadiotherapy Planning, Computer-AssistedRadiotherapy DosageOrgans at Risk

Autor:innen und Institutionen

  • Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada.
  • Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada.

ORCID-Profile: Vickie Kong

Zitieren

APA

Kong, V., Dang, J., Wan, V., & Rosewall, T. (2023). The dosimetric underpinning of bladder filling criteria for prostate image-guided volumetric modulated arc therapy. The British Journal of Radiology, 96(1146). https://doi.org/10.1259/bjr.20230020

Vancouver

Kong V, Dang J, Wan V, Rosewall T. The dosimetric underpinning of bladder filling criteria for prostate image-guided volumetric modulated arc therapy. The British Journal of Radiology. 2023;96(1146). doi:10.1259/bjr.20230020

BibTeX
@article{Kong2023,
  author = {Kong, Vickie and Dang, Jennifer and Wan, Vanessa and Rosewall, Tara},
  title = {The dosimetric underpinning of bladder filling criteria for prostate image-guided volumetric modulated arc therapy},
  journal = {The British Journal of Radiology},
  year = {2023},
  volume = {96},
  number = {1146},
  doi = {10.1259/bjr.20230020}
}