EUVIMEDEUVIMED entdecken
Netzwerk-MetaanalyseSystematische Übersicht

Diagnostic Accuracy of Vascular Ultrasonography for Postanesthesia Induction Hypotension: A Systematic Review and Network Meta-Analysis

Raoul Schorer, Arni Ibsen, Andres Hagerman, Christoph Ellenberger, Alessandro Putzu

Anesthesia & Analgesia · 2025

DOI: 10.1213/ane.0000000000007108 ↗

Kurz gefasst

Netzwerk-Metaanalyse in der Zeitschrift Anesthesia & Analgesia, 2025. Verfasst von Raoul Schorer und 4 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Anesthesiology, Pharmacology, Intensive Care and Emergency Medicine, University Hospitals of Geneva, Geneva, Switzerland. Hauptthemen laut MEDLINE: Hypotension. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 67 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Arterial hypotension commonly occurs after anesthesia induction and is associated with negative clinical outcomes. Point-of-care ultrasound examination has emerged as a modality to predict postinduction hypotension (PIH). We performed a systematic review and network meta-analysis of the predictive performance of point-of-care ultrasound tests for PIH in noncardiac, nonobstetrical routine adult surgery. METHODS: Online databases were searched for diagnostic test accuracy studies of point-of-care ultrasound for predicting PIH up to March 30, 2023. The systematic review followed the Cochrane methodology. A Bayesian diagnostic test accuracy network meta-analysis model was used, with PIH as defined by study authors as the main outcome. Risk of bias and applicability were examined through the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) score. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework was used to assess evidence certainty. RESULTS: A total of 32 studies with 2631 participants were eligible for systematic review. Twenty-six studies with 2258 participants representing 8 ultrasound tests were included in the meta-analysis. Inferior vena cava collapsibility index (22 studies) sensitivity was 60% (95% credible interval [CrI], 49%–72%) and specificity was 83% (CrI, 74%–89%). Carotid artery corrected flow time (2 studies) sensitivity was 91% (CrI, 76%–98%) and specificity was 90% (CrI, 59%–98%). There were serious bias and applicability concerns due to selection bias and inappropriate blinding. The certainty of evidence was very low for all tests. CONCLUSIONS: The predictive performance of point-of-care ultrasound for PIH is uncertain. There is a need for high-quality randomized controlled trials with appropriate blinding and void of selection bias.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HypotensionHumansPoint-of-Care SystemsPredictive Value of TestsReproducibility of ResultsUltrasonography

Autor:innen und Institutionen

  • From the Department of Anesthesiology, Pharmacology, Intensive Care and Emergency Medicine, University Hospitals of Geneva, Geneva, Switzerland.
  • Faculty of Medicine, University of Geneva, Geneva, Switzerland.

Zitieren

APA

Schorer, R., Ibsen, A., Hagerman, A., Ellenberger, C., & Putzu, A. (2025). Diagnostic Accuracy of Vascular Ultrasonography for Postanesthesia Induction Hypotension: A Systematic Review and Network Meta-Analysis. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000007108

Vancouver

Schorer R, Ibsen A, Hagerman A, Ellenberger C, Putzu A. Diagnostic Accuracy of Vascular Ultrasonography for Postanesthesia Induction Hypotension: A Systematic Review and Network Meta-Analysis. Anesthesia & Analgesia. 2025. doi:10.1213/ane.0000000000007108

BibTeX
@article{Schorer2025,
  author = {Schorer, Raoul and Ibsen, Arni and Hagerman, Andres and Ellenberger, Christoph and Putzu, Alessandro},
  title = {Diagnostic Accuracy of Vascular Ultrasonography for Postanesthesia Induction Hypotension: A Systematic Review and Network Meta-Analysis},
  journal = {Anesthesia & Analgesia},
  year = {2025},
  doi = {10.1213/ane.0000000000007108}
}
Kostenlos starten →