EUVIMEDEUVIMED entdecken
Vergleichsstudie

Accuracy of point-of-care-ultrasound performed by physicians in the diagnosis of deep vein thrombosis

Serhat Örün iD, Cihan Aydın iD, Aykut Demirkıran iD, Mehmet Çelik

Vascular · 2025

DOI: 10.1177/17085381251342387 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Vascular, 2025. Verfasst von Serhat Örün und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency, Faculty of Medicine Tekirdağ Namık Kemal University, Tekirdağ, Turkey. Hauptthemen laut MEDLINE: Venous Thrombosis, Point-of-Care Systems, Point-of-Care Testing. Die Arbeit nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The diagnosis of deep vein thrombosis (DVT) is usually made by a sonographer using a thorough Doppler ultrasound. The current study examined whether emergency resident physicians could accurately diagnose DVT using a point-of-care, three-point compression protocol.

Methods

The patient population consisted of patients with suspected DVT who presented to the emergency department between 2021 and 2022. All patients underwent a three-point compression ultrasound exam by the emergency resident. Each patient then had a comprehensive whole-leg ultrasonography exam performed by a supervisor emergency specialist. The results of the ultrasound exams by the emergency resident physicians and comprehensive exams were then analyzed and compared.

Results

The average age of the patients was 60,96 ± 16,67. There was a statistically significant difference between three-point compression and whole-leg ultrasound examination data. The negative predictive value of the resident physician was determined as 94%. The coefficient of the compression variable in the Ridge regression analysis for diagnosing DVT in the whole-leg ultrasound examination was obtained as −0.3754.

Conclusions

We think that compression ultrasonography may be sufficient in patient management compared to whole-leg ultrasonography in emergency management. However, we think that three-point compression ultrasonography applied by the emergency resident is quite successful in diagnosing and excluding DVT in the emergency department.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Venous ThrombosisPoint-of-Care SystemsPoint-of-Care TestingHumansMalePredictive Value of TestsMiddle AgedFemaleAgedReproducibility of ResultsUltrasonographyEmergency Service, HospitalClinical CompetenceAged, 80 and overAdultInternship and ResidencyRetrospective Studies

Stichwörter der Autor:innen

Emergency ultrasounddeep venous thrombosislimited duplex examinationthree-point compression

Autor:innen und Institutionen

  • Department of Emergency, Faculty of Medicine Tekirdağ Namık Kemal University, Tekirdağ, Turkey.
  • Department of Cardiology, Faculty of Medicine Tekirdağ Namık Kemal University, Tekirdağ, Turkey.

ORCID-Profile: Serhat Örün, Cihan Aydın, Aykut Demirkıran

Zitieren

APA

Örün, S., Aydın, C., Demirkıran, A., & Çelik, M. (2025). Accuracy of point-of-care-ultrasound performed by physicians in the diagnosis of deep vein thrombosis. Vascular. https://doi.org/10.1177/17085381251342387

Vancouver

Örün S, Aydın C, Demirkıran A, Çelik M. Accuracy of point-of-care-ultrasound performed by physicians in the diagnosis of deep vein thrombosis. Vascular. 2025. doi:10.1177/17085381251342387

BibTeX
@article{rn2025,
  author = {Örün, Serhat and Aydın, Cihan and Demirkıran, Aykut and Çelik, Mehmet},
  title = {Accuracy of point-of-care-ultrasound performed by physicians in the diagnosis of deep vein thrombosis},
  journal = {Vascular},
  year = {2025},
  doi = {10.1177/17085381251342387}
}
Kostenlos starten →