Determining the accuracy of the leukocyte esterase reagent strip test in the rapid diagnosis of adult septic arthritis
Advances in Rheumatology · 2024
DOI: 10.1186/s42358-024-00409-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advances in Rheumatology, 2024. Verfasst von Peyman Mirghaderi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Surgical Research Society (SRS), Students' Scientific Research Center, Tehran University of Medical Sciences, Tehran, Iran. Hauptthemen laut MEDLINE: Arthritis, Infectious, Carboxylic Ester Hydrolases, Reagent Strips, Sensitivity and Specificity. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Backgrounds Septic arthritis is a dangerous disease that occurs when microorganisms enter synovial fluid. It needs fast and accurate management; otherwise, it can harm the patient’s life. Currently, the tests measure WBC and PMN in SF, so we hypothesized to use a proxy that is easier and faster to measure. Leukocyte esterase is an enzyme secreted by neutrophils that can be found in the synovial fluid of SA patients. In this study, we tried to investigate the sensitivity and specificity of leukocyte esterase in diagnosing septic arthritis.
Methods
We obtained synovial fluid samples from forty-six patients suspected of having septic arthritis and fifty-eight healthy individuals and measured the WBCs, ESR, CRP, PMN, glucose, and protein of SF in 2021. We also used the leukocyte esterase dipstick test to investigate the level of LE in synovial fluid for one minute.
Results
Based on clinical and paraclinical criteria, sixteen out of the forty-six patients were diagnosed with SA. When (++) was considered positive, the sensitivity and specificity of the LE dipstick test for the diagnosis of SA were 93.7% (95% CI: 81.8–100%) and 60% (95% CI: 42.4–77.5%, P = 0.000), respectively. When both (+) and (++) were considered positive, they were 100% and 43.3% (95% CI: 25.6–61.0% P = 0.000), respectively. All the patients in the control group had negative cultures and LE test readings (specificity = 100%).
Conclusion
The LE dipstick test can be a valuable diagnostic tool in the initial diagnosis of SA since it is affordable, fast, and reliable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Surgical Research Society (SRS), Students' Scientific Research Center, Tehran University of Medical Sciences, Tehran, Iran.
- Joint Reconstruction Research Center, Imam Khomeini Hospital, Tehran, Iran.
- Joint Reconstruction Research Center, Imam Khomeini Hospital, Tehran, Iran. smjmort@yahoo.com.
ORCID-Profile: Peyman Mirghaderi, Mohammad-Taha Pahlevan-Fallahy, S M Javad Mortazavi
Zitieren
APA
Mirghaderi, P., Pahlevan-Fallahy, M. T., Mahmoudi, J., & Mortazavi, S. M. J. (2024). Determining the accuracy of the leukocyte esterase reagent strip test in the rapid diagnosis of adult septic arthritis. Advances in Rheumatology. https://doi.org/10.1186/s42358-024-00409-4
Vancouver
Mirghaderi P, Pahlevan-Fallahy MT, Mahmoudi J, Mortazavi SMJ. Determining the accuracy of the leukocyte esterase reagent strip test in the rapid diagnosis of adult septic arthritis. Advances in Rheumatology. 2024. doi:10.1186/s42358-024-00409-4
BibTeX
@article{Mirghaderi2024,
author = {Mirghaderi, Peyman and Pahlevan-Fallahy, Mohammad-Taha and Mahmoudi, Jamil and Mortazavi, S M Javad},
title = {Determining the accuracy of the leukocyte esterase reagent strip test in the rapid diagnosis of adult septic arthritis},
journal = {Advances in Rheumatology},
year = {2024},
doi = {10.1186/s42358-024-00409-4}
}
EUVIMED