EUVIMEDEUVIMED entdecken
Evaluationsstudie

Evaluation of a fully automated multiplex PCR panel for the microbiological diagnosis of joint infections

Narumi Ueda, Yasushi Nakamori, Kazuyuki Okuda, Hirokazu Iida, Tetsuro Sugiura, Takanori Saito

Journal of Orthopaedic Science · 2026

DOI: 10.1016/j.jos.2025.12.004 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Orthopaedic Science, 2026. Verfasst von Narumi Ueda und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Japanese Red Cross Wakayama Medical Center, 4-20 Komatsubara-dori, Wakayama-city, Wakayama 640-8558, Japan. Electro…. Hauptthemen laut MEDLINE: Multiplex Polymerase Chain Reaction, Arthritis, Infectious, Synovial Fluid. Die Arbeit nennt 43 Literaturangaben. Gefördert von: bioMérieux, Kansai Medical University, Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

AIMS: Rapid identification of the causative microorganisms of osteoarticular infections is essential for successful treatment. BIOFIRE® FilmArray® Joint Infection Panel (JI panel), a fully automated multiplex PCR panel, can rapidly detect pathogens and antimicrobial resistance genes in the synovial joints in patients with acute osteoarticular infections. Accordingly, this study aimed to evaluate the diagnostic method of the JI panel in patients with osteoarticular infections. METHODS: Synovial fluid samples were collected from patients with suspected osteoarticular infections. Fifty-five samples from 49 patients were analysed. The JI panel results were compared with those obtained using conventional culture methods. RESULTS: The sensitivities of the JI panel and culture for detecting microorganisms were 55 and 61 %, respectively, while the specificities were both 100 %. For patients with osteoarticular infections (n = 23) and positive culture or JI panel, the agreement rate between the JI panel and culture was 65 %. In five samples (22 %), the culture was positive, but the JI panel was negative. In three of the five JI panel-negative specimens (13 %), the bacteria identified in the culture were not included in the panel design. Three culture-negative specimens were JI panel-positive. Significantly higher sensitivity (70 % vs. 55 %; P = 0.008) was observed with the combined JI panel and culture than with the JI panel alone. CONCLUSION: The JI panel is a useful technique to identify causative bacteria rapidly and automatically, but the combination of the JI panel and culture methods is recommended because some pathogens are not included in the JI panel. LEVEL OF EVIDENCE: Diagnostic level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Multiplex Polymerase Chain ReactionArthritis, InfectiousSynovial FluidHumansFemaleSensitivity and SpecificityMaleMiddle AgedAgedAdultAged, 80 and over

Stichwörter der Autor:innen

Fracture-related infectionMultiplex PCR panelOsteoarticular infectionPeriprosthetic joint infectionSeptic arthritisSurgical site infection

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Japanese Red Cross Wakayama Medical Center, 4-20 Komatsubara-dori, Wakayama-city, Wakayama 640-8558, Japan. Electronic address: narumi0303@gmail.com.
  • Department of Genome Analysis Center, Kansai Medical University Medical Center, 10-15 Fumizono-cho, Moriguchi, Osaka 570-8507, Japan; Department of Emergency and Critical Care Medicine, Kansai Medical University Medical…
  • Department of Genome Analysis Center, Kansai Medical University Medical Center, 10-15 Fumizono-cho, Moriguchi, Osaka 570-8507, Japan.
  • Department of Rehabilitation, Kansai Medical University, 18-89, Uyamahigashi-cho, Hirakata, Osaka 573-1136, Japan.
  • Department of Medicine II, Kansai Medical University Medical Center, 10-15 Fumizono-cho, Moriguchi, Osaka 570-8507, Japan.
  • Department of Orthopedic Surgery Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan.

Förderung

  • bioMérieux
  • Kansai Medical University
  • Japan Society for the Promotion of Science

Zitieren

APA

Ueda, N., Nakamori, Y., Okuda, K., Iida, H., Sugiura, T., & Saito, T. (2026). Evaluation of a fully automated multiplex PCR panel for the microbiological diagnosis of joint infections. Journal of Orthopaedic Science. https://doi.org/10.1016/j.jos.2025.12.004

Vancouver

Ueda N, Nakamori Y, Okuda K, Iida H, Sugiura T, Saito T. Evaluation of a fully automated multiplex PCR panel for the microbiological diagnosis of joint infections. Journal of Orthopaedic Science. 2026. doi:10.1016/j.jos.2025.12.004

BibTeX
@article{Ueda2026,
  author = {Ueda, Narumi and Nakamori, Yasushi and Okuda, Kazuyuki and Iida, Hirokazu and Sugiura, Tetsuro and Saito, Takanori},
  title = {Evaluation of a fully automated multiplex PCR panel for the microbiological diagnosis of joint infections},
  journal = {Journal of Orthopaedic Science},
  year = {2026},
  doi = {10.1016/j.jos.2025.12.004}
}
Kostenlos starten →