EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Bedside zero-fluoroscopy temporary permanent pacemaker implantation in the electrical storm treatment under the guidance of EnSite 3D system: a case report

Lei Wang, Pengfei Li, Jun Li, Jicheng Xi, Zhibiao Zhang, Fang Yan, Yanan Zhang, Haixiong Wang, Huiyuan Han

Journal of Cardiothoracic Surgery · 2024

DOI: 10.1186/s13019-024-02579-0 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Cardiothoracic Surgery, 2024. Verfasst von Lei Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Shanxi Cardiovascular Hospital, 18 Yifen Road, Taiyuan, Shanxi, 030001, China. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Tachycardia, Ventricular. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shanxi Provincial Natural Science Basic Research Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Electrical storm (ES) is a clinical emergency characterized by multiple malignant ventricular arrhythmias or ICD discharges within 24 h, requiring early rational management. Case presentation We report a 55-year-old man who underwent aortic valve replacement experienced recurrent ventricular tachycardia/ventricular fibrillation. A temporary permanent pacemaker with the EnSite system was implanted, and significant inhibition of the electrical storm, attributed to the atrial overdrive pacing, ensued.

Conclusions

In emergency regarding an electrical storm, the bedside temporary permanent pacemaker implantation with the EnSite system is concluded to be feasible and safe.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialTachycardia, VentricularMaleHumansMiddle AgedAortic ValveFluoroscopyTreatment OutcomeCardiac Pacing, Artificial

Stichwörter der Autor:innen

Electrical stormNavigation systemTemporary pacing

Autor:innen und Institutionen

  • Department of Cardiology, Shanxi Cardiovascular Hospital, 18 Yifen Road, Taiyuan, Shanxi, 030001, China.
  • Department of Cardiology, Xinzhou People's Hospital, Xinzhou, Shanxi, 034000, China.
  • Department of Cardiac Surgery, Shanxi Cardiovascular Hospital, Taiyuan, Shanxi, 030001, China.
  • Department of Critical Medicine, Shanxi Bethune Hospital, Taiyuan, Shanxi, 030001, China.
  • Department of Cardiology, Shanxi Cardiovascular Hospital, 18 Yifen Road, Taiyuan, Shanxi, 030001, China. cz1976whx@126.com.
  • Department of Cardiology, Xinzhou People's Hospital, Xinzhou, Shanxi, 034000, China. cz1976whx@126.com.

Förderung

  • Shanxi Provincial Natural Science Basic Research Program

Zitieren

APA

Wang, L., Li, P., Li, J., Xi, J., Zhang, Z., Yan, F., Zhang, Y., Wang, H., & Han, H. (2024). Bedside zero-fluoroscopy temporary permanent pacemaker implantation in the electrical storm treatment under the guidance of EnSite 3D system: a case report. Journal of Cardiothoracic Surgery. https://doi.org/10.1186/s13019-024-02579-0

Vancouver

Wang L, Li P, Li J, Xi J, Zhang Z, Yan F, et al. Bedside zero-fluoroscopy temporary permanent pacemaker implantation in the electrical storm treatment under the guidance of EnSite 3D system: a case report. Journal of Cardiothoracic Surgery. 2024. doi:10.1186/s13019-024-02579-0

BibTeX
@article{Wang2024,
  author = {Wang, Lei and Li, Pengfei and Li, Jun and Xi, Jicheng and Zhang, Zhibiao and Yan, Fang and Zhang, Yanan and Wang, Haixiong and Han, Huiyuan},
  title = {Bedside zero-fluoroscopy temporary permanent pacemaker implantation in the electrical storm treatment under the guidance of EnSite 3D system: a case report},
  journal = {Journal of Cardiothoracic Surgery},
  year = {2024},
  doi = {10.1186/s13019-024-02579-0}
}
Kostenlos starten →