EUVIMEDObjevte EUVIMED
Randomisierte kontrollierte StudieMultizentrische StudieVergleichsstudieOpen access · CC BY-NC-ND 4.0

Femoral neck system versus cannulated screws combined with medial plate for femoral neck fractures in young and middle-aged patients: a prospective multicenter randomized controlled trial

Mingyu Wen, Shengying Wang, Lihua Wang, Yuhai Wang, Shiyou Dai, Wen Liu, Xiao Fan

Journal of Orthopaedic Surgery and Research · 2025-06-03 · 20 (1)

DOI: 10.1186/s13018-025-05972-0 ↗

At a glance

Randomisierte kontrollierte Studie in Journal of Orthopaedic Surgery and Research, published online on 2025-06-03. Written by Mingyu Wen and 6 co-authors. Institution: Qingdao University, Qingdao, 266011, China. Major MEDLINE topics: Femoral Neck Fractures, Bone Screws, Bone Plates, Fracture Fixation, Internal. Cited 6 times so far (Crossref); 55 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: The Young Talent Support Project of Shandong Province Medical Association.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

BACKGROUND: Femoral neck system (FNS) and cannulated screws combined with medial plate (CS with medial plate) both are commonly used internal fixation for femoral neck fractures in recent years. There is a debate that which is the better choice for young and middle-aged patients with femoral neck fractures. The objective of the study is to compare clinical effects of FNS and CS with medial plate on young and middle-aged patients with femoral neck fractures by a prospective multicenter randomized controlled trial for the first time. METHODS: Patients between 18 and 65 years old with femoral neck fractures were allocated to FNS fixation and CS with medial plate fixation with 2 years follow-up. The primary outcomes included fracture bone union rate and Harris hip score. The secondary outcomes included Garden's alignment index, surgical data, Barthel index, visual analogue scale (VAS), gait analysis and complications during follow-up. Statistical analysis was performed by multiple linear regression and logistics regression. RESULTS: 165 patients in FNS group and 166 patients in CS with medial plate group were analyzed finally. There was no statistical difference in bone union rate, Garden's alignment index, Barthel index, gait analysis between two groups. The FNS group had a higher Harris hip score at 3 months after operation (P < 0.05), lower surgical data including operation time, intraoperative blood loss and fluoroscopy frequency (P < 0.001) and lower VAS at 1 month after operation (P < 0.05) than that of CS with medial plate group, but no significant difference at 3, 6, 12, and 24 months. There was no statistical difference in the incidence of complications between groups, except the incidence of coxa vara, which is higher in FNS group (P < 0.05). CONCLUSIONS: For young and middle-aged patients with femoral neck fractures, both FNS and CS combined with a medial plate are effective. TRIAL REGISTRATION: ChiCTR2100042960, registered 1 February 2021, http://www.chictr.org.cn .

Subjects

MeSH terms (MEDLINE)

Femoral Neck FracturesBone ScrewsBone PlatesFracture Fixation, InternalHumansMaleFemaleMiddle AgedAdultProspective StudiesYoung AdultTreatment OutcomeAgedFollow-Up StudiesAdolescent

Author keywords

Bone screwsFemoral neck fracturesFemoral neck systemMedial plateRandomized controlled trial

Authors and institutions

  • Qingdao University, Qingdao, 266011, China.
  • Qingdao Municipal Hospital, No.1 Jiaozhou Road, Qingdao, 266011, China.
  • Fuzhou Second Hospital, Fuzhou, 350007, China.
  • People's Hospital of Ningxia Hui Autonomous Region, Yinchuan, 750002, China.
  • Qingdao Municipal Hospital, No.1 Jiaozhou Road, Qingdao, 266011, China. daishiyou2023@126.com.
  • Qingdao Municipal Hospital, No.1 Jiaozhou Road, Qingdao, 266011, China. 28636279@qq.com.

Funding

  • The Young Talent Support Project of Shandong Province Medical Association

Cite

APA

Wen, M., Wang, S., Wang, L., Wang, Y., Dai, S., Liu, W., & Fan, X. (2025). Femoral neck system versus cannulated screws combined with medial plate for femoral neck fractures in young and middle-aged patients: a prospective multicenter randomized controlled trial. Journal of Orthopaedic Surgery and Research, 20(1). https://doi.org/10.1186/s13018-025-05972-0

Vancouver

Wen M, Wang S, Wang L, Wang Y, Dai S, Liu W, et al. Femoral neck system versus cannulated screws combined with medial plate for femoral neck fractures in young and middle-aged patients: a prospective multicenter randomized controlled trial. Journal of Orthopaedic Surgery and Research. 2025;20(1). doi:10.1186/s13018-025-05972-0

BibTeX
@article{Wen2025,
  author = {Wen, Mingyu and Wang, Shengying and Wang, Lihua and Wang, Yuhai and Dai, Shiyou and Liu, Wen and Fan, Xiao},
  title = {Femoral neck system versus cannulated screws combined with medial plate for femoral neck fractures in young and middle-aged patients: a prospective multicenter randomized controlled trial},
  journal = {Journal of Orthopaedic Surgery and Research},
  year = {2025},
  volume = {20},
  number = {1},
  doi = {10.1186/s13018-025-05972-0}
}
Start for free →