Fachartikel in der Zeitschrift Journal of Orthopaedic Surgery and Research, 2025. Verfasst von Mandi Cai und 7 weiteren Autor:innen. Beteiligte Einrichtung: The First School of Clinical Medicine, Southern Medical University, No.1838 North of Guangzhou Road, Guangzhou, 510515, People's Republic of China. Hauptthemen laut MEDLINE: Finite Element Analysis, Atlanto-Axial Joint, Joint Dislocations, Pedicle Screws. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Guangdong Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Background
C1-C2 pedicle screw-rod fixation (PSR) is widely used for atlantoaxial dislocations. However, its limited reduction capacity in refractory cases necessitates additional release surgeries, increasing operative risks including prolonged surgical time and expanded tissue damage. We developed a novel Z-shaped anti-rotation rod to improve reduction capability, but its biomechanical performance requires evaluation.
Methods
A nonlinear atlantoaxial instability three-dimensional (3D) C0-C3 finite element model was constructed using computed tomography images from a 25-year-old healthy male without a history of cervical spine diseases. Based on this model, two C1-C2 fixation configurations were simulated: conventional pedicle screw-rod (PS-CR) and pedicle screw-Z-shaped rod (PS-ZR). Reduction forces were measured and compared. Range of motion (ROM), stress distribution and peak stress values of the implants were recorded and compared under six loading conditions including flexion, extension, lateral bending, and axial rotation.
Results
Both configurations achieved a greater than 98% reduction in the C1-C2 segmental ROM, with similar compensatory motions in adjacent segments. The reduction force of PS-ZR showed significant advantages (2–8 mm range), achieving a maximum reduction force of 88.544 N, which is 1.67 to 3.68 times that of PS-CR. The PS-ZR system experiences greater stress compared to the PS-CR system, escalating with Z-rod height. Regarding stress distribution and peak values of rods, the maximum stress on the PS-CR system was mainly concentrated at the connection between the rod and the screw nut while the maximum stress on the PS-ZR system was concentrated at the transition part of the “Z” shape.
Conclusions
Both PS-CR and PS-ZR configurations provide reliable and comparable stability. Compared to the PS-CR configuration, the PS-ZR configuration provides superior reduction force and stability, potentially reducing the need for additional release surgery and surgical time. This novel design has significant clinical implications for improving fixation techniques.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The First School of Clinical Medicine, Southern Medical University, No.1838 North of Guangzhou Road, Guangzhou, 510515, People's Republic of China.
- Department of Orthopedics, General Hospital of Southern Theatre Command of PLA, 111 Liuhua Road, Guangzhou, 510010, People's Republic of China.
- Department of Orthopedics, General Hospital of Southern Theatre Command of PLA, 111 Liuhua Road, Guangzhou, 510010, People's Republic of China. zouxb6478@126.com.
- The First School of Clinical Medicine, Southern Medical University, No.1838 North of Guangzhou Road, Guangzhou, 510515, People's Republic of China. maxy1001@126.com.
- Department of Orthopedics, General Hospital of Southern Theatre Command of PLA, 111 Liuhua Road, Guangzhou, 510010, People's Republic of China. maxy1001@126.com.
Förderung
- Natural Science Foundation of Guangdong Province
- National Natural Science Foundation of China
Zitieren
APA
Cai, M., Ma, R., Chen, J., Huang, X., Zhang, Y., Xie, Z., Zou, X., & Ma, X. (2025). A novel Z-shaped anti-rotation rod for atlantoaxial dislocation reduction: finite element analysis. Journal of Orthopaedic Surgery and Research. https://doi.org/10.1186/s13018-025-05723-1
Vancouver
Cai M, Ma R, Chen J, Huang X, Zhang Y, Xie Z, et al. A novel Z-shaped anti-rotation rod for atlantoaxial dislocation reduction: finite element analysis. Journal of Orthopaedic Surgery and Research. 2025. doi:10.1186/s13018-025-05723-1
BibTeX
@article{Cai2025,
author = {Cai, Mandi and Ma, Rencai and Chen, Junlin and Huang, Xinzhao and Zhang, Yixing and Xie, Zhuohang and Zou, Xiaobao and Ma, Xiangyang},
title = {A novel Z-shaped anti-rotation rod for atlantoaxial dislocation reduction: finite element analysis},
journal = {Journal of Orthopaedic Surgery and Research},
year = {2025},
doi = {10.1186/s13018-025-05723-1}
}
EUVIMED