First real-time imaging of bronchoscopic lung volume reduction by electrical impedance tomography
Respiratory Research · 2024
DOI: 10.1186/s12931-024-02877-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Respiratory Research, 2024. Verfasst von Vinicius Torsani und 13 weiteren Autor:innen. Beteiligte Einrichtung: Divisao de Pneumologia, Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil. Hauptthemen laut MEDLINE: Electric Impedance, Bronchoscopy. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação de Amparo à Pesquisa do Estado de São Paulo, Grantová Agentura České Republiky.
Abstract (Originalsprache)
Background
Bronchoscopic lung volume reduction (BLVR) with one-way endobronchial valves (EBV) has better outcomes when the target lobe has poor collateral ventilation, resulting in complete lobe atelectasis. High-inspired oxygen fraction (F I O 2 ) promotes atelectasis through faster gas absorption after airway occlusion, but its application during BLVR with EBV has been poorly understood. We aimed to investigate the real-time effects of F I O 2 on regional lung volumes and regional ventilation/perfusion by electrical impedance tomography (EIT) during BLVR with EBV.
Methods
Six piglets were submitted to left lower lobe occlusion by a balloon-catheter and EBV valves with F I O 2 0.5 and 1.0. Regional end-expiratory lung impedances (EELI) and regional ventilation/perfusion were monitored. Local pocket pressure measurements were obtained (balloon occlusion method). One animal underwent simultaneous acquisitions of computed tomography (CT) and EIT. Regions-of-interest (ROIs) were right and left hemithoraces.
Results
Following balloon occlusion, a steep decrease in left ROI-EELI with F I O 2 1.0 occurred, 3-fold greater than with 0.5 ( p < 0.001). Higher F I O 2 also enhanced the final volume reduction (ROI-EELI) achieved by each valve ( p < 0.01). CT analysis confirmed the denser atelectasis and greater volume reduction achieved by higher F I O 2 (1.0) during balloon occlusion or during valve placement. CT and pocket pressure data agreed well with EIT findings, indicating greater strain redistribution with higher F I O 2 .
Conclusions
EIT demonstrated in real-time a faster and more complete volume reduction in the occluded lung regions under high F I O 2 (1.0), as compared to 0.5. Immediate changes in the ventilation and perfusion of ipsilateral non-target lung regions were also detected, providing better estimates of the full impact of each valve in place.
Trial registration
Not applicable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Divisao de Pneumologia, Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil.
- Division of Thoracic Surgery, Thoracic Surgery Research Laboratory (LIM 61), Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, Brasil.
- Institute of Physiology, First Faculty of Medicine, Charles University, Albertov 5, Prague, 128 00, Czech Republic. joaobatistaborges8@gmail.com.
- Biomedical Engineering Laboratory, Escola Politecnica da Universidade de Sao Paulo, Sao Paulo, Brasil.
- Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA.
- Institute of Physiology, First Faculty of Medicine, Charles University, Albertov 5, Prague, 128 00, Czech Republic.
Förderung
- Fundação de Amparo à Pesquisa do Estado de São Paulo
- Grantová Agentura České Republiky
Zitieren
APA
Torsani, V., Cardoso, P. F. G., Borges, J. B., Gomes, S., Moriya, H. T., Cruz, A. F. D., Santiago, R. R. S., Nagao, C. K., Fitipaldi, M. F., Beraldo, M. D. A., Junior, M. H. V., Mlček, M., Pego-Fernandes, P. M., & Amato, M. B. P. (2024). First real-time imaging of bronchoscopic lung volume reduction by electrical impedance tomography. Respiratory Research. https://doi.org/10.1186/s12931-024-02877-0
Vancouver
Torsani V, Cardoso PFG, Borges JB, Gomes S, Moriya HT, Cruz AFD, et al. First real-time imaging of bronchoscopic lung volume reduction by electrical impedance tomography. Respiratory Research. 2024. doi:10.1186/s12931-024-02877-0
BibTeX
@article{Torsani2024,
author = {Torsani, Vinicius and Cardoso, Paulo Francisco Guerreiro and Borges, João Batista and Gomes, Susimeire and Moriya, Henrique Takachi and Cruz, Andrea Fonseca da and Santiago, Roberta Ribeiro de Santis and Nagao, Cristopher Kengo and Fitipaldi, Mariana Fernandes and Beraldo, Marcelo do Amaral and Junior, Marcus Henrique Victor and Mlček, Mikuláš and Pego-Fernandes, Paulo Manuel and Amato, Marcelo Britto Passos},
title = {First real-time imaging of bronchoscopic lung volume reduction by electrical impedance tomography},
journal = {Respiratory Research},
year = {2024},
doi = {10.1186/s12931-024-02877-0}
}
EUVIMED