EUVIMEDEUVIMED entdecken
Crossref

Evaluating lung ventilation via electrical impedance tomography during flexible bronchoscopy with supraglottic jet ventilation: a prospective pilot study

Yang Gu, Xiaowei Zhang, Xiang Li, Keting Min, Huimin Deng, Di Feng, Huanping Zhou, Juan Wei, Xin Lv

Journal of Anesthesia · 2025

DOI: 10.1007/s00540-025-03568-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Anesthesia, 2025. Verfasst von Yang Gu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Shanghai Pulmonary Hospital, School of Medicine, Tongji University, 507 Zhengmin Road, Shanghai, 200043, China. Hauptthemen laut MEDLINE: Bronchoscopy, Electric Impedance, High-Frequency Jet Ventilation, Tomography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Clinical Research Plan of SHDC, Program of Shanghai Academic Research Leader, Teaching Reform Research Project of Shanghai Pulmonary Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Supraglottic jet ventilation (SJV) is used during flexible bronchoscopy to improve oxygenation, but its impact on overall lung ventilation is unclear. Thoracic electrical impedance tomography (EIT) offers real-time monitoring of respiratory function. METHODS: This prospective pilot study enrolled patients undergoing flexible bronchoscopy. End-expiratory lung impedance (EELI) changes from baseline (ΔEELI) were measured at baseline (T0), oxygenation with Wei nasal jet (WNJ) (T1), SJV (T2), during bronchoscopy (T3), and post-bronchoscopy (T4). The primary outcome was ΔEELI at T2 vs. T3. Secondary outcomes included ΔEELI at other time points, ventilation distribution (ventral vs. total lung, ROIventral), hemodynamics, oxygen saturation (SpO2) at each point, and adverse events. RESULTS: Among 27 patients, 5 experienced transient desaturation (no laryngeal mask ventilation needed). ΔEELI and SpO2 significantly decreased from T2-T3 (ΔEELI: -2.65, 95% CI -4.27 to -1.02, p < 0.001; SpO2: -2.5%, 95% CI -4.7 to -0.3%, p < 0.001). Conversely, ΔEELI and SpO2 significantly increased from T1-T2 (ΔEELI: 1.84, 95% CI 1.02-2.66, p < 0.001; SpO2: 3.3%, 95% CI 1.3-5.2%, p < 0.001), with ROIventral rising from 43.7 to 60.4% (16.6% increase, 95% CI 4.4-28.9%, p < 0.001). CONCLUSIONS: While SJV did not prevent the negative effects of bronchoscopy on lung ventilation and oxygenation, it maintained adequate SpO2. Pre-bronchoscopy SJV improved these measures, but shifted ventilation towards ventral lung regions compared to WNJ oxygenation. TRIAL REGISTRATION: Chinese Clinical Trial Registry (URL: Chictr.org.cn), Identifier: ChiCTR2100050285. Date of registration: Aug 25th, 2021.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BronchoscopyElectric ImpedanceHigh-Frequency Jet VentilationTomographyLungPulmonary VentilationHumansPilot ProjectsProspective StudiesMaleFemaleMiddle AgedAgedAdultOxygen Saturation

Stichwörter der Autor:innen

Electrical impedance tomographyFlexible bronchoscopySupraglottic jet ventilation

Autor:innen und Institutionen

  • Department of Anesthesiology, Shanghai Pulmonary Hospital, School of Medicine, Tongji University, 507 Zhengmin Road, Shanghai, 200043, China.
  • Department of Anesthesiology, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai, China.
  • Department of Anesthesiology, The First Affiliated Hospital of Anhui Medical University, Hefei, China.
  • Department of Pulmonary and Critical Care Medicine, Shanghai Pulmonary Hospital, School of Medicine, Tongji University, Shanghai, China.
  • Department of Anesthesiology, Shanghai Pulmonary Hospital, School of Medicine, Tongji University, 507 Zhengmin Road, Shanghai, 200043, China. sudaweijuan@163.com.
  • Department of Anesthesiology, Shanghai Pulmonary Hospital, School of Medicine, Tongji University, 507 Zhengmin Road, Shanghai, 200043, China. xinlvg@126.com.

Förderung

  • Clinical Research Plan of SHDC
  • Program of Shanghai Academic Research Leader
  • Teaching Reform Research Project of Shanghai Pulmonary Hospital
  • Clinical Research Special Project of Shanghai Municipal Health Commission

Zitieren

APA

Gu, Y., Zhang, X., Li, X., Min, K., Deng, H., Feng, D., Zhou, H., Wei, J., & Lv, X. (2025). Evaluating lung ventilation via electrical impedance tomography during flexible bronchoscopy with supraglottic jet ventilation: a prospective pilot study. Journal of Anesthesia. https://doi.org/10.1007/s00540-025-03568-w

Vancouver

Gu Y, Zhang X, Li X, Min K, Deng H, Feng D, et al. Evaluating lung ventilation via electrical impedance tomography during flexible bronchoscopy with supraglottic jet ventilation: a prospective pilot study. Journal of Anesthesia. 2025. doi:10.1007/s00540-025-03568-w

BibTeX
@article{Gu2025,
  author = {Gu, Yang and Zhang, Xiaowei and Li, Xiang and Min, Keting and Deng, Huimin and Feng, Di and Zhou, Huanping and Wei, Juan and Lv, Xin},
  title = {Evaluating lung ventilation via electrical impedance tomography during flexible bronchoscopy with supraglottic jet ventilation: a prospective pilot study},
  journal = {Journal of Anesthesia},
  year = {2025},
  doi = {10.1007/s00540-025-03568-w}
}
Kostenlos starten →