EUVIMEDObjevte EUVIMED
VergleichsstudieOpen access · CC BY-NC-ND 4.0

Comparative evaluation of four traction scenarios on a labially impacted dilacerated maxillary central incisor: a three-dimensional finite element analysis

Enas Senan Alyafrusee, Bowen Zheng, Wael Telha, Mengyao Li, Haopeng Wu, Xiaofeng Yang, Bushra Sufyan Almaqrami, Naseem Ali Al-Worafi, Majedh Abdo Ali Al-Somairi, Maged S Alhammadi, Yi Liu

BMC Oral Health · 2025-05-22 · 25 (1)

DOI: 10.1186/s12903-025-05966-8 ↗

At a glance

Vergleichsstudie in BMC Oral Health, published online on 2025-05-22. Written by Enas Senan Alyafrusee and 10 co-authors. Institution: Department of Orthodontics, School and Hospital of Stomatology, Liaoning Provincial Key Laboratory of Oral Disease, China Medical University, Shenyan…. Major MEDLINE topics: Finite Element Analysis, Incisor, Tooth, Impacted, Imaging, Three-Dimensional. Cited 8 times so far (Crossref); 41 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

OBJECTIVE: This study aimed to analyze the stress distribution in the dentoalveolar structures of a labially impacted dilacerated maxillary central incisor during orthodontic traction, considering different positions of the traction button on the tooth's crown through finite element analysis (FEA). MATERIALS AND METHODS: Four three-dimensional (3D)finite element models (FEM) were created to simulate the maxilla of a 9-year-old female patient, featuring a left labially impacted dilacerated maxillary central incisor with the only variation being the position of the orthodontic traction button: at the incisal third of the labial surface (Model A), at the incisal third of the palatal surface (Model B), at the middle third of the palatal surface (Model C), and the cervical third of the palatal surface (Model D). Material parameters, grids, boundary conditions, coordinate systems, and load conditions were set in Ansys to establish the FEM for traction of the impacted incisor. A 100 g total traction force was applied between the button and a 0.016 × 0.022-inch stainless steel archwire in the direction perpendicular to the impacted tooth's crown. The initial tooth displacements, biomechanical stress at the root apex, alveolar bone von Mises stress, and hydrostatic stress of the periodontal ligament (PDL) under the four conditions were analyzed and compared. RESULTS: The impact of traction button positioning on tooth displacement, stress distribution, and bone loading was assessed in four models. Model B demonstrated the highest labiopalatal and vertical displacement. The stress concentrations in the impacted tooth's root were highest in model B, particularly in the cervical region labially, while model D showed the lowest root stress. Maximum stress in the alveolar bone was also observed in models A and B, particularly on the palatal surface near the cervical region. Hydrostatic stress in the periodontal ligament was highest in model B and lowest in model D. CONCLUSION: The traction button positioned on the incisal third of the labial or palatal surface facilitates significant tooth movement. Still, it carries a higher risk of periodontal ligament damage, root and alveolar bone resorption. In contrast, the traction button positioned on the cervical third of the palatal surface, while less effective for movement, generates the least stress.

Subjects

MeSH terms (MEDLINE)

Finite Element AnalysisIncisorTooth, ImpactedImaging, Three-DimensionalDental Stress AnalysisOrthodontic ExtrusionTooth Movement TechniquesHumansFemaleChildMaxillaStress, MechanicalOrthodontic WiresBiomechanical PhenomenaTooth CrownPeriodontal LigamentAlveolar ProcessTooth RootComputer SimulationTooth Apex

Author keywords

DilacerationHydrostatic stress of periodontal ligamentImpacted maxillary central incisorStress distributionThree-dimensional finite element analysis

Authors and institutions

  • Department of Orthodontics, School and Hospital of Stomatology, Liaoning Provincial Key Laboratory of Oral Disease, China Medical University, Shenyang, Liaoning, 110002, China.
  • Shenyang Clinical Medical Research Center of Orthodontic Disease, Shenyang, Liaoning, 110002, China.
  • Department of Orthodontics and Dentofacial Orthopedics, Faculty of Dentistry, Ibb University, IBB, Yemen.
  • Department of Orthodontics, School and Hospital of Stomatology, Liaoning Provincial Key Laboratory of Oral Disease, China Medical University, Shenyang, Liaoning, 110002, China. bwzheng@cmu.edu.cn.
  • Shenyang Clinical Medical Research Center of Orthodontic Disease, Shenyang, Liaoning, 110002, China. bwzheng@cmu.edu.cn.
  • Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Thamar University, Thamar, Yemen.

Cite

APA

Alyafrusee, E. S., Zheng, B., Telha, W., Li, M., Wu, H., Yang, X., Almaqrami, B. S., Al-Worafi, N. A., Al-Somairi, M. A. A., Alhammadi, M. S., & Liu, Y. (2025). Comparative evaluation of four traction scenarios on a labially impacted dilacerated maxillary central incisor: a three-dimensional finite element analysis. BMC Oral Health, 25(1). https://doi.org/10.1186/s12903-025-05966-8

Vancouver

Alyafrusee ES, Zheng B, Telha W, Li M, Wu H, Yang X, et al. Comparative evaluation of four traction scenarios on a labially impacted dilacerated maxillary central incisor: a three-dimensional finite element analysis. BMC Oral Health. 2025;25(1). doi:10.1186/s12903-025-05966-8

BibTeX
@article{Alyafrusee2025,
  author = {Alyafrusee, Enas Senan and Zheng, Bowen and Telha, Wael and Li, Mengyao and Wu, Haopeng and Yang, Xiaofeng and Almaqrami, Bushra Sufyan and Al-Worafi, Naseem Ali and Al-Somairi, Majedh Abdo Ali and Alhammadi, Maged S and Liu, Yi},
  title = {Comparative evaluation of four traction scenarios on a labially impacted dilacerated maxillary central incisor: a three-dimensional finite element analysis},
  journal = {BMC Oral Health},
  year = {2025},
  volume = {25},
  number = {1},
  doi = {10.1186/s12903-025-05966-8}
}
Start for free →