EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Influence of guide support on the accuracy of static Computer-Assisted Implant Surgery (sCAIS) in partially edentulous cases using a keyless guiding system: an in vitro study

David Kasradze, Ricardas Kubilius

BMC Oral Health · 2025

DOI: 10.1186/s12903-025-05955-x ↗

At a glance

Journal article in BMC Oral Health, 2025. Written by David Kasradze and 1 co-authors. Institution: Department of Maxillofacial Surgery, Lithuanian University of Health Sciences, Eiveniu Street 2, Kaunas, 50161, Lithuania. david.kasradze@lsmu.lt. Major MEDLINE topics: Surgery, Computer-Assisted, Dental Implantation, Endosseous, Jaw, Edentulous, Partially. Cited 5 times so far (Crossref); 41 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

PURPOSE: To evaluate the influence of guide support on the accuracy of sCAIS using a keyless guiding system in different cases of partial edentulism. METHODS: Sixty polyamide models of partially edentulous maxillae, simulating anterior and posterior single-tooth gaps as well as anterior and distal extended edentulous areas, were fabricated. Full-arch, 2-teeth, and 4-teeth supported surgical guides were used to place implants at FDI 15, 17, 21, 26 sites in Model A and at FDI 12, 22, 15 sites in Model B. In total, 210 replica implants were placed using 120 surgical guides in seven implantation sites. Three-dimensional crestal and apical, angular and vertical deviations from the planned implant positions were compared using the Kruskal-Wallis H test with Dunn's procedure for multiple pairwise comparisons. RESULTS: Overall median 3D crestal and apical deviations of implants placed with 2-teeth guide support (0.62 mm [0.45-0.84], 0.92 mm [0.69-1.25]) and 4-teeth guide support (0.65 mm [0.52-0.81], 1.01 mm [0.8-1.26]) were significalty lower compared to the full-arch support group (0.86 mm [0.63-0.98], 1.26 mm [0.98-1.52]) with values of p < 0.017. Overall angular and vertical deviations of implants placed with 2-teeth guide support (2.61° [1.71-3.75], 0.32 mm [0.15-0.44]) were significantly lower compare to the full-arch support group (3.22° [2.25-4.41], 0.46 mm [0.24-0.62]). In the subgroup analysis, implants placed at the FDI 12, 22, and 15 positions exhibited significantly higher 3D and angular deviations with full-arch guide support, whereas the 3D apical and angular deviations of were significantly lower with 2-teeth guide support at the FDI 21 site. CONCLUSIONS: The deviations in all guide support groups did not exceed the recommended safety margins. Statistically significant differences were found between guide support groups, with influence of guide support on the accuracy of sCAIS varying across different implantation sites. TRIAL REGISTRATION: Not applicable.

Subjects

MeSH terms (MEDLINE)

Surgery, Computer-AssistedDental Implantation, EndosseousJaw, Edentulous, PartiallyHumansMaxillaIn Vitro TechniquesDental ImplantsModels, DentalImaging, Three-Dimensional

Author keywords

Guide supportGuided implant placementImplantologyPartial edentulismStatic Computer-Assisted Implant Surgery

Substances

Dental Implants

Authors and institutions

  • Department of Maxillofacial Surgery, Lithuanian University of Health Sciences, Eiveniu Street 2, Kaunas, 50161, Lithuania. david.kasradze@lsmu.lt.
  • Department of Maxillofacial Surgery, Lithuanian University of Health Sciences, Eiveniu Street 2, Kaunas, 50161, Lithuania.

Cite

APA

Kasradze, D., & Kubilius, R. (2025). Influence of guide support on the accuracy of static Computer-Assisted Implant Surgery (sCAIS) in partially edentulous cases using a keyless guiding system: an in vitro study. BMC Oral Health. https://doi.org/10.1186/s12903-025-05955-x

Vancouver

Kasradze D, Kubilius R. Influence of guide support on the accuracy of static Computer-Assisted Implant Surgery (sCAIS) in partially edentulous cases using a keyless guiding system: an in vitro study. BMC Oral Health. 2025. doi:10.1186/s12903-025-05955-x

BibTeX
@article{Kasradze2025,
  author = {Kasradze, David and Kubilius, Ricardas},
  title = {Influence of guide support on the accuracy of static Computer-Assisted Implant Surgery (sCAIS) in partially edentulous cases using a keyless guiding system: an in vitro study},
  journal = {BMC Oral Health},
  year = {2025},
  doi = {10.1186/s12903-025-05955-x}
}
Start for free →