Micro-CT evaluation of dentinal microcrack formation in mesiobuccal canals of maxillary molars following instrumentation with heat-treated rotary and reciprocating systems
BMC Oral Health · 2025
DOI: 10.1186/s12903-025-05929-z ↗Kurz gefasst
Fachartikel in der Zeitschrift BMC Oral Health, 2025. Verfasst von Fatemeh Soltaninejad und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran. Hauptthemen laut MEDLINE: X-Ray Microtomography, Molar, Root Canal Preparation, Dentin. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The goal of root canal preparation is to eliminate microorganisms and debris from the root canal system, while providing space for the placement of root filling materials. However, the process can lead to the formation of dentin microcracks, increasing the risk of vertical root fractures. This study used micro-CT to evaluate the formation of dentinal microcracks following instrumentation with One Curve, EdgeOne Fire, and VDW.ROTATE systems.
Methods
Thirty-three extracted maxillary molars with non-calcified Vertucci type 4 s mesiobuccal canals were included. After pre-instrumentation micro-CT scans, a single endodontist prepared the canals with three aforementioned rotary systems. Post-instrumentation scans were conducted and axial sections from both the pre- and post-preparation scans were analyzed by two blinded observers to identify newly formed microcracks. Cohen’s Kappa coefficient assessed interobserver agreement and dentinal microcracks were evaluated using ANOVA, ANCOVA, Kruskal-Wallis, and McNemar’s test ( P < 0.05).
Results
All three rotary systems led to significant increases in dentinal microcracks post-instrumentation. While the VDW.ROTATE group showed a slightly higher percentage of cracked Sect. (72%), statistical analysis showed no significant difference between the groups ( P = 0.35).
Conclusion
Preparation of maxillary molar root canals using different rotary systems resulted in the formation of dentin microcracks, with no significant correlation to the specific system used.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Endodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
- Research Committee, School of Dentistry, Shahid Beheshti University of Medical Sciences, Daneshju Blvd., Velenjak St., Chamran Highway, Tehran, 1983963113, Iran.
- Research Committee, School of Dentistry, Shahid Beheshti University of Medical Sciences, Daneshju Blvd., Velenjak St., Chamran Highway, Tehran, 1983963113, Iran. Sepehr78mb@gmail.com.
Zitieren
APA
Soltaninejad, F., Shantiaee, Y., Zandi, B., Moslemi, A., & Mirebeigi-Jamasbi, S. S. (2025). Micro-CT evaluation of dentinal microcrack formation in mesiobuccal canals of maxillary molars following instrumentation with heat-treated rotary and reciprocating systems. BMC Oral Health. https://doi.org/10.1186/s12903-025-05929-z
Vancouver
Soltaninejad F, Shantiaee Y, Zandi B, Moslemi A, Mirebeigi-Jamasbi SS. Micro-CT evaluation of dentinal microcrack formation in mesiobuccal canals of maxillary molars following instrumentation with heat-treated rotary and reciprocating systems. BMC Oral Health. 2025. doi:10.1186/s12903-025-05929-z
BibTeX
@article{Soltaninejad2025,
author = {Soltaninejad, Fatemeh and Shantiaee, Yazdan and Zandi, Babak and Moslemi, Arsham and Mirebeigi-Jamasbi, Seyed Sepehr},
title = {Micro-CT evaluation of dentinal microcrack formation in mesiobuccal canals of maxillary molars following instrumentation with heat-treated rotary and reciprocating systems},
journal = {BMC Oral Health},
year = {2025},
doi = {10.1186/s12903-025-05929-z}
}
EUVIMED