In vitro assessment of the accuracy of two intra-oral scanners for post space scanning in a fully digital workflow
BMC Oral Health · 19.03.2025 · 25 (1)
DOI: 10.1186/s12903-025-05723-x ↗Kurz gefasst
Fachartikel in der Zeitschrift BMC Oral Health, online erschienen am 19.03.2025. Verfasst von Mennatallah Wahba und 1 weiteren Autor:innen. Beteiligte Einrichtung: Fixed Prosthodontics Department, Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt. menna.mohie@fue.edu.eg. Hauptthemen laut MEDLINE: Computer-Aided Design, Post and Core Technique, Dental Prosthesis Design. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Future University in Egypt.
Abstract (Originalsprache)
Background
With the rapid advancements in computer-aided imaging, the potential for chairside fabrication of custom-made posts utilizing intraoral scanners may offer a reliable alternative to traditional physical impressions. Accordingly, this study aimed to evaluate the accuracy (trueness and precision) of two intra-oral scanners when different post space diameters were employed. Additionally, the scan depth of each intra-oral scanner (IOS) was assessed.
Methods
An endodontically treated mandibular canine was inserted in a printed typodont model and prepared with two post-space diameters; a small one (1.5 mm) and a large one (2 mm). Polyvinyl siloxane impressions for the two post-space diameters were taken and then scanned with an extra-oral scanner to serve as reference scans. Each post-space diameter was scanned using CEREC Primescan ( n = 8) and Medit i700 ( n = 8) intra-oral scanners. Standard tessellation language (STL) files of all intra-oral and extra-oral scans were uploaded to a 3D matching program to evaluate trueness, precision, and post-space length difference. Statistical analysis was performed using different tests for parametric and non-parametric data. The significance level was set at P < 0.05.
Results
Regarding the effect of the IOS and the effect of the post-space diameter, both Medit i700 and the small diameter groups using both scanners showed significantly higher root mean square (RMS) values when evaluating trueness. For precision, Medit i700 showed a significantly higher RMS value in the large diameter group. Medit i700 showed a significantly higher difference in post-space length than Primescan in both diameters. Primescan recorded a zero difference in the large diameter group compared to the reference scan.
Conclusions
The IOS type and the post-space diameter influenced the scan accuracy and the depth of the scan. Accuracy results were superior when Primescan was implemented for scanning the large diameter post-space subgroup.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Fixed Prosthodontics Department, Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt. menna.mohie@fue.edu.eg.
- Fixed Prosthodontics Department, Faculty of Dentistry, Cairo University, Cairo, Egypt.
- Fixed Prosthodontics Division, School of Dentistry, New Giza University, Cairo, Egypt.
Förderung
- Future University in Egypt
Zitieren
APA
Wahba, M., & ElBasty, R. S. (2025). In vitro assessment of the accuracy of two intra-oral scanners for post space scanning in a fully digital workflow. BMC Oral Health, 25(1). https://doi.org/10.1186/s12903-025-05723-x
Vancouver
Wahba M, ElBasty RS. In vitro assessment of the accuracy of two intra-oral scanners for post space scanning in a fully digital workflow. BMC Oral Health. 2025;25(1). doi:10.1186/s12903-025-05723-x
BibTeX
@article{Wahba2025,
author = {Wahba, Mennatallah and ElBasty, Reham Said},
title = {In vitro assessment of the accuracy of two intra-oral scanners for post space scanning in a fully digital workflow},
journal = {BMC Oral Health},
year = {2025},
volume = {25},
number = {1},
doi = {10.1186/s12903-025-05723-x}
}
EUVIMED