The effect of aging on the translucency of contemporary zirconia generations: in-vitro study
BMC Oral Health · 2024
DOI: 10.1186/s12903-024-04465-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift BMC Oral Health, 2024. Verfasst von Aya A Salama und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Fixed Prosthodontics, October University for Modern Sciences and Arts, Giza, Egypt. ayasaad@msa.edu.eg. Hauptthemen laut MEDLINE: Zirconium, Materials Testing. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: October University for Modern Sciences and Arts.
Abstract (Originalsprache)
Background
The translucency of different zirconia generations at each time point after thermocycling aging is still lacking.
Methods
Four zirconia materials were used with a total of 60 samples produced from monolithic third generation (5Y) 5 mol% yttria-stabilized zirconia polycrystalline ceramic and fourth generation zirconia (4Y) 4 mol% yttria-stabilized zirconia polycrystalline ceramic, represented by [group1:[CM-5Y] Ceramill Zolid fx (3rd generation zirconia) (Amann Girrbach, Koblach, Austria), group 2:[CM-4Y] Ceramill Zolid HT + (4th generation zirconia) (Amann Girrbach, Koblach, Austria), group 3:[CC-5Y] Cercon XT/ML (Dentsply Sirona, Germany) (3rd generation), and group 4:[CC-4Y] Cercon HT/ML (Dentsply Sirona, Germany) (4th generation)]. The L*a*b* figures were measured by using a spectrophotometer at baseline and after 10,000, 30,000, and 50,000 cycles of thermocycling. At each interval, the translucency of the samples was estimated by using the translucency formula CIEDE2000. The Scheffe post-hoc compared differences among each of the four materials. The Repeated measures ANOVA tested the differences between the materials at each of the different thermocycling intervals ( p < .001). Data analyses were evaluated at a significance level of p < .05 (CI 95%).
Results
Two-way ANOVA revealed that at baseline the third and fourth generation’s zirconia showed statistically significant differences in translucency ( P < .001). Translucency values at baseline and after thermocycling exhibited statistically significant changes ( p = .003). At each of the time interval; CM-4Y had the highest translucency values followed by CM-5Y, CC-4Y and CC-5Y had the least translucency values.
Conclusions
The third and fourth generations of zirconia displayed different translucencies. Thermocycling affected the translucency of both third and fourth generations of zirconia. At each of the time intervals group 2:[CM-4Y] had the highest TP followed by group1:[CM-5Y], while, group 3:[CC-5Y] and group 4:[CC-4Y] had the least TP.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Fixed Prosthodontics, October University for Modern Sciences and Arts, Giza, Egypt. ayasaad@msa.edu.eg.
- Lecturer of Orthodontics, October University for Modern Sciences and Arts, Giza, Egypt.
- Department of Fixed Prosthodontics, October University for Modern Sciences and Arts, Giza, Egypt.
Förderung
- October University for Modern Sciences and Arts
Zitieren
APA
Salama, A. A., Shehab, K. A., Bushra, S. S., & Hamza, F. S. (2024). The effect of aging on the translucency of contemporary zirconia generations: in-vitro study. BMC Oral Health. https://doi.org/10.1186/s12903-024-04465-6
Vancouver
Salama AA, Shehab KA, Bushra SS, Hamza FS. The effect of aging on the translucency of contemporary zirconia generations: in-vitro study. BMC Oral Health. 2024. doi:10.1186/s12903-024-04465-6
BibTeX
@article{Salama2024,
author = {Salama, Aya A and Shehab, Karim A and Bushra, Sherif Samir and Hamza, Faisal Safwat},
title = {The effect of aging on the translucency of contemporary zirconia generations: in-vitro study},
journal = {BMC Oral Health},
year = {2024},
doi = {10.1186/s12903-024-04465-6}
}
EUVIMED